Search results

  1. 2

    Dewalt DCN660N 2nd fix nail gun for Cedar cladding?

    Yes I have many Dewalt XR tools.
  2. 2

    Dewalt DCN660N 2nd fix nail gun for Cedar cladding?

    Hi all. I have Dewalt tools and want to invest in a nail gun for cladding my extension in cedar. I will be using stainless nails for secret fixing of 18mm cedar. Will the Dewalt DCN660 2nd fix gun be suitable for the job? Cheers
  3. 2

    Connecting new DPC to existing...

    Thanks very much!
  4. 2

    Connecting new DPC to existing...

    Thanks DAZB so I need to rake out 100mm into the existing wall and overlap new with existing. I haven't got an architect, submitted my own plans to building control where I mentioned that new DPC will meet old which was approved, but I see plenty of videos where the builders do not rake out the...
  5. 2

    Connecting new DPC to existing...

    Hi all Couple of questions regarding DPC. I am building an extension which will consist of a timber internal leaf and blockwork external leaf, I have laid the first course of blocks and im at the DPC of the existing brick built house. 1) When connecting the new DPC to the existing, should I...
  6. 2

    What grade concrete for raft foundation/

    Hi all Soon I will order the concrete for my 22m2 raft foundation. The raft will support a single story part blockwork part timber extension. My structural engineer says C25 grade concrete will be suitable however it would only be £30 extra to go with C30 and £80 extra in total to go with C35...
  7. 2

    Any other reason to blind type 1 other than to protect dpm?

    Hi All I am in the middle of constructing a raft foundation for my extension. My DPM will sit on top of the slab below the insulation and screed so that I can tie it into the external leaf blockwork as my internal leaf will be timber. Probably a stupid question but is the only purpose of...
  8. 2

    Tying membrane under a raft into the wall

    Hi Steve I am in exactly the same scenario as you were, what did you go with in the end? Cheers
  9. 2

    Build Over - Please can someone validate my drawings

    Hi! How did you get on with this build over application? Any issues? I am about to submit something very similar :giggle:
  10. 2

    Footings: Large lintel bridging public sewers and soil pipes

    I sense some sarcasm? :LOL: That drawing isn't quite accurate, the sewers would remain supported by the ground underneath and a compressible material on top of some sort. I see pee shingle seems to be used a lot, or maybe fibreglass. I will ask the water board what they want me to use.
  11. 2

    Footings: Large lintel bridging public sewers and soil pipes

    Thankyou Jeds, I will do that. The current connection is not accessible without excavating and a man hole cover will be put in place next to the extension just after the soil pipe bend. Thanks for your input
  12. 2

    Footings: Large lintel bridging public sewers and soil pipes

    Hi All I am planning a rear single story extension and I have 2 public sewers which run under where I need to build. This is no issue as I have been advised by Anglian Water how they are to be protected when building over. The issue I have is my property's sewer pipe joins the main public sewer...
  13. 2

    Wood burning stove Flue travelling along wall

    Hi All I cant find any regulation info on wood burning stove flues running along walls horrizontally. I am hoping to build a lean too extension with a wood burning stove in one corner. I want to run a 150mm double skin flue out of the top of the wall, along the external wall following the 15...
  14. 2

    Building over two sewers. The 6m rule

    Hi Everyone. There are two public sewers running across my garden where I plan to build a single story extension. According to all of Anglian waters rules on their website, I cant see any reason why my application to build over the sewers may be rejected, assuming I protect the sewers with a...
  15. 2

    Undergroup external garden building

    Hi! Thanks for your responses. I was hoping that building underground without having to excavate would allow me to build over 15m3. If no excavation is required, can I exceed this as the space already exists? If I build above ground, I am limited to 15m3 and will have to fill the space in...
  16. 2

    Undergroup external garden building

    Hi All There is a very large ditch which runs across the end of the gardens of the houses on my road. The ditch has a very small stream within it (just boggy, no visible water running). The ditch is about 10m long x 5m wide x 8 foot deep. The houses either side of me have installed a concrete...
Back