  1. A

    Sounder Connections to 9751 Panel

    Hello, I wish to wire the following items to my scantronic 9751 panel. 2 pyronix Deltabell plus external sounders. 1 pyronix internal speaker/sounder. Please correct me if i'm wrong but do each of the outputs (OP1-OP3) on the 9751 panel provide 500mA each? In that case I should be able to...
  2. A

    New Spur Connection for Underfloor heating in bathroom

    Thanks, I will check with my electrician.
  3. A

    New Spur Connection for Underfloor heating in bathroom

    Yeh bathroom has already got a decent sized towel rail radiator, so heating is no problem, the mat was just to add comfort on the chilliest of mornings ;-)
  4. A

    New Spur Connection for Underfloor heating in bathroom

    [/url] Thank you for your reply Taylortwocities, I'm glad to hear the connection will be fine. Re; complaince with building regulations, I am getting my CU upgraded to RCD protection, as I understand that 30mA RCD protection is a requirement for new bathroom electrical renovations. I've...
  5. A

    New Spur Connection for Underfloor heating in bathroom

    Hello all, I have installed a Devimat 500W UFH system in my upstairs bathroom & plan to wire it up in the form of a spur from a single power socket outside the bathroom. (This is the most easiest & convenient option as opposed to connecting directly to the CU downstairs). I will be installing...
  6. A

    New Keypad for Scantronic 9800+ control panel

    Sorry to sound stupid, but how do I go about sending a PM to you...? I cannot seem to find your mail add. regards
  7. A

    New Keypad for Scantronic 9800+ control panel

    Hello all, Can anyone please recommend a replacement keypad for my Scantronic 9800+ control Panel. The current Keypad (9827) is playing up & the buttons are sticking/playing up when entering the user code. I believe the 9827 keypad are now obsolete. Thanks
  8. A

    Is Epoxy grout suitable for Underfloor heating?

    Thank you chaps.....
  9. A

    Is Epoxy grout suitable for Underfloor heating?

    Good Morning, Just have a quick question on whether epoxy grout is suitable for use with underfloor heating. I am about to grout my wetroom floor (900mm X 900mm) which is heated, and am considering using Mapei Kerapoxy epoxy grout. Any responses kindly appreciated. Regards
  10. A

    New Basin Pop up waste leaking

    Hello all, I've just fitted a new basin with pop up waste, but it still leaks a little from the bottom treads. The waste has a white sealing ring which sits into the basin as you tighten. A rubber ring and a plastic tightening nut secures it from under the basin. I've tightened it as tight as...
  11. A

    Connecting shower pump to Basin mixer tap

    Hi Gasguru, thanks for your reply. I just checked on the grundfos website, on there there is a shower selection guide, and my pump's the STP-2.0 version with twin impellers. It mentions on there that its suitable for up to two bathroom suites, i.e Basin/bath taps/ shower mixer tap. Heres the...
  12. A

    Connecting shower pump to Basin mixer tap

    Hello all, I have a question whether I can connect my shower pump to the basin mixer tap in the bathroom. I have already connected the pump to the shower, and was wondering whether I can tee off to also supply to the basin. The pump I'm using is a Grundfos Amazon 2.0 Bar Twin Impellar Brass...
  13. A

    Connecting SD1 speech diallar to Scantronic 9751 panel

    Hello all, I'm not very clear on the trigger connections of the SD1 to a scantronic 9751 panel. I know that the SD1 requires negative trigger to dial out. I wish to connect the triggers to the fire detector, Panic attack, and a PIR circiut. Do I connect the relevant trigger wires on the SD1 to...
  14. A

    Honeywell T70 Hot Water Cylinder Thermostat wiring question

    Thanks for the quick reply heatserve. That now makes sense. The Thermostat is made of Plastic & I'LL cover the wire with red tape. regards
  15. A

    Honeywell T70 Hot Water Cylinder Thermostat wiring question

    Dear all, I have fully pumped hot water system with a Honeywell T70 Cylinder Thermostat and a Honeywell 3 port diverter valve (V4073A). I was inspecting the wiring and noted that earth wire from the T70 cylinder thermostat is connected to a brown wire (I presume its Live) going to a...
  16. A

    Wet pressure testing of new copper pipes

    Thanks for the reply guys, much appreciated.
  17. A

    Wet pressure testing of new copper pipes

    Thanks Tamz, Thats exactly what I did. just turned on the water to see if there are any leaks. I did find one slow leak at an elbow, and after fixing it, has compelled me to go for the pressure testing for total peace of mind! Bearing in mind that the hot & cold pipes exiting the shower...
  18. A

    Wet pressure testing of new copper pipes

    Hello all, I want to pressure test my bathroom shower/sink pipe fittings using a manual wet pressure tester (which I'LL hire), before sealing the floorboards. I want to ensure the soldered joints are strong and free of any leaks. All the pipes are in copper/soldered (except the ones...