  1. P

    damp concrete floor and tiles

    Hi we have a small back kitchen with a concrete floor - originally this was the washouse so i doubt it has a DPC. later they built an extension next to this room and must have filled in the gap between the new room and old room with concrete - doubt this has a DPC. Both areas are about a 1...
  2. P

    lime and plasterboard

    Can you use a lime finishing coat (as used to set a lime plastered wall) on conventional plasterboard????????? Lime is so much less of an adrenalin rush than normal finishing coats. Thanks
  3. P

    plastering to a wooden edge

    Hi can you help me? we are putting horizontal t+g panelling along the rafter slope in an upstairs room, then plasterboarding and skimming the walls to either side. I am stuck with the detail where plaster board meets wood panelling. 1. do we take the plaster to the panelling or the...
  4. P

    rafter condensation/dehumidifier

    we are doing a rennovation on an old stone house with bit felt /sarking and slate roof. Have put insuation between rafters and now have so much condensation that it is like a frozen sheet of ice on the inside of the sarking! we are putting in slate vents at present. the inside walls...
  5. P

    screwfix copper pipe

    Is screwfix copper pipe inferior to other pipe for heating circuit - it is so much cheaper - should it be avoided? cheers
  6. P

    immersion timer

    Good point - rather incredible that my own brain didn't make that connection! You have to wonder at yourself sometimes ehy.
  7. P

    immersion timer

    Am I right in saying then that if my timer is set to activate immersion between 1300 and 1600 it will only actually come on during these times when the water is below a certain temp? Can you give me some names of good immersion timers. Cheers
  8. P

    immersion timer

    is it possible to have a timer that will activate the immersion at certain times of day but only if the water in tank is below a certain temp. Thus allowing the immersion to be used as a hot water back up but only at times of day when the elec is cheaper. not sure if this is the right forum but...
  9. P

    loft insulation

    Thanks for clearing up my confusion on that matter - you set out to do something that all the wiring manuals present as alogical task and then hit on the real details of it all and feel a bit overwhelmed!
  10. P

    loft insulation

    Have read the kevin boone cable selector in For refernce only to find the reader wouldn't show the tables of cables! will try a friend comp. Can I just clarify what you mean by the cable being under-run. We have 3 5A lighting fuseholders in the CU, each circuit is run in 1.0mm cable and has...
  11. P

    loft insulation

    Was going to run elec cables to inside (room side) of wall insulation so that they would be accessible if necessary. Present cables run I think under rafter insulation which is also the slope in the bedroom roof upstairsand down inside of insulation. There is no loft insulation and I wanted to...
  12. P

    loft insulation

    so if the cables are clipped clear what about the section of cable that runs through the insulation to be the bedroom light for example - here there would be say 225mm of cable running through the insulation to go throught the ceiling. is it a problem in a standard house with say 3 x 1.0mm...
  13. P

    loft insulation

    Should all elec cables in loft run on the outside (cold side) of the thermal loft insulation?
  14. P

    split lighting feed / 2 gang

    Found discussion of this in a post and can't find it again! Lighting circuit Feed goes to JB (off this comes 1 light/1switch) feed continues onto next JB (off this comes 1 light/1switch) feed continues onto next JB where it splits into 2 feeds. These 2 feeds go to 2 JBs (last on circuit)...
  15. P

    mixing lighting cable sizes

    should elec cables in loft be to the outside of the loft insulation?
  16. P

    mixing lighting cable sizes

    Each of the 3 JB's which each feed 6-7 lights go back to the meter and meet their own 5A fuseholder. I will check cable size in electic shop - there is such a slight difference that I just wondered if there was a definite way of working out if you have 1.0mm or 1.5mm rather than using eye...
  17. P

    mixing lighting cable sizes

    Have got 2 lights in hall coming off a multi terminal junction box. The switch is 1 gang 1 way also coming from that junction box. I want to add a 3rd porch light cable into the junction box and put a 2 gang switch wired from the junction box with a 3 core wire so the 3 core will operate the 2...
  18. P

    3 core 2 gang 2 way

    Cheers, 2 3core wires it is
  19. P

    3 core 2 gang 2 way

    Sorry! To make it simpler I have 2 lights cables running to a JB from there a 3 core switch cable runs to one 2 gang switch where it is wired for 1 way switching (by a red live loop from one gang to the other gang.) What I want to know is if I can make these 2 light switches into 2 way...
  20. P

    3 core 2 gang 2 way

    Excuse my long winded explanation Can you help me? At present I have a 2 gang switch that operates 2 lights 1 way this is wired from the JB with one 3 core wire as follows Light 1 red connects to yellow from switch cable black to common light2 red connects to blue from switch cable...