  1. S

    Indesit IWDE7125 Fault Code 15

    Rocks1 thanks for that I have checked the dryer element today and no reading with the meter so looks like it has gone faulty. Looks OK on the outside but obviously gone. When I took the whole dryer section off with the fan the plastic bit it sits on was full off fluff I have cleared out as best...
  2. S

    Indesit IWDE7125 Fault Code 15

    Thank you for the replies rocks1 I will check tomorrow
  3. S

    Indesit IWDE7125 Fault Code 15

    The fault occurs on any cycle now. Originally the wife said that it has only happened on the drying cycle but I have put it on the drain cycle which is only a couple of minutes and it clicks to check the door lock then makes a "groaning noise" which does not sound normal then makes another...
  4. S

    Indesit IWDE7125 Fault Code 15

    I have had a look to see what this fault code is and it seems it is to do with the drying heater relay but different machines have a different meaning for this fault code. Can anyone confirm that the code 15 is definitely a dryer heating relay issue for my make of washer dryer. Thank you in...
  5. S

    Vax air issue with water in the dirt container bin.

    Hi Hopefully someone will be able to solve an issue that has just happened. My wife has done the vacuuming today and noticed some water in the dirt container bin today. The dirt inside the container was just not wet, there was water in the bottom of the container. She did some hovering this...
  6. S

    Garage consumer unit query

    Thank you all for taking the time to respond. I never really use the garage sockets, the only time it is used is for turning on the lights when the wife put's her bike away. The two times it has caused the RCB to trip we have not been in the garage and if my memory serves me well it may have...
  7. S

    Garage consumer unit query

    Hi I have a Hager VC202 consumer unit in the garage with 2 connections (not switches but pull down with fuses inside). The issue I have had is that the main unit in the house has tripped a couple of times and when I turn it back on, sometimes it will not stay on until I turn off the garage...
  8. S

    Veritas R8 alarm query

    Secureiam you input has been much appreciated. I have input all the information you sent and can now walk around without the system going off. I do believe you were right in your earlier when you said about entering the engineer code a couple of times that was probably in my panic to stop the...
  9. S

    Veritas R8 alarm query

    Zone 1 is doors both front and side door which leads into the utility Zone 2 is the PIR in the hallway which is where the front door is and the keypad Zone 3 is the PIR in the kitchen Zone 4 is the PIR in the lounge (patio doors to garden are not alarmed) Zone 5 is the PIR in the dining room...
  10. S

    Veritas R8 alarm query

    The control panel is under the stairs and the keypad is by the front door in the hallway, the PIR in the hallway is connected to number 2 on the panel and this was the one that was causing the issue. The alarm has never worked since we moved into the house as when I put the fuse in, it started...
  11. S

    Veritas R8 alarm query

    Hi I have fitted a new battery in my Veritas R8 control panel. I switched it on and managed to put in the default code and also the engineers code from all the installation information that I downloaded. With the panel unset and walking in the hallway it seems to trigger the alarm so there must...
  12. S

    Veritas R8 control panel?Texecom D5010 - 02.05 (PCB345) battery query

    Hi I have a Texecom D5010 - 02.05 control panel with a Veritas R8 keypad which I have not had chance to look at until today since we moved into the property. My question is what battery should be used as there is not one inside for me to match against. I have managed to download a copy of the...
  13. S

    2D 4 pin CFL lamp converting to LED starter holder query

    Thank you all for the responses much appreciated
  14. S

    2D 4 pin CFL lamp converting to LED starter holder query

    Hi I am looking at fitting LED lights as replacements for CFL tubes currently installed. I have seen that I will need to bypass the electric ballast unit which is straight forward on the light fittings I have. My question is apart from removing the starter from the starter holder do I have to...
  15. S

    Paint came off onto roller when painting above shower

    Thanks for the response Misterhelpful I was unsure how to resolve this so thanks for the solution.
  16. S

    Paint came off onto roller when painting above shower

    Hi I started painting the ceiling above the shower today not because it was flaking but just to freshen it up. Wish I had not bothered as when I rolled the area above the shower the paint came of onto the roller. There was no sign of flaking before so I never expected any problems. What is...
  17. S

    What to inhibitor to put in a central heating system

    Thank you for the replies. I was just unsure as to what I could put in the system due to it being a sealed system.
  18. S

    What to inhibitor to put in a central heating system

    Hi Looking for some advice of what I can put into the central heating system. At my old house which had a basic boiler and was an indirect system I periodically had Sentinal X100 inhibitor in the system and when I moved the Potterton Kingfisher boiler was still going strong after nearly 20...