Search results

  1. flameport

    Blanki g cooker isolation under sink to pass EICR

    AI slop which mostly creates stories some people might believe.
  2. flameport

    3 electric showers

    Stored hot water in a cylinder, either unvented if the cold supply is suitable, or pumped if not. Heated via your combi boiler. Certainly not, and even two of them is likely to be overloading the supply.
  3. flameport

    T4 and t5

    Fluorescent tubes of all types are obsolete. Don't spend any time or money on them.
  4. flameport

    Outside Christmas Lights

    The 3000 set is rated for 36 volts, and that is what that power supply provides. Whether they are 'dull' or not is unrelated, that's how they are designed.
  5. flameport

    Are these C2s or C3s

    Pretty much correct, and the reality is that that 1970s wooden cased fusebox should have been replaced several decades ago.
  6. flameport

    Why would I want to wire a pneumatic switch pair in a two-way configuration?

    Instructions copied from some other switch instructions. Or it's AI generated slop. Or both.
  7. flameport

    BT phone line/service 'upgrade'

    Money laundering or other criminal coverups.
  8. flameport

    What fire rated downlights are you all fitting?

    No. So the millions of properties that have pendant lighting will get a low rated EPC. As will those that have any other types of light fitting with G9, G4, GU10 and all the other styles of replaceable lamps, and all because someone might go and buy some inefficient incandescent lamps that...
  9. flameport

    Walk-in shower screen

    Gravity and the fact it is fixed to the tray with silicone.
  10. flameport

    Planning Q

    Phase balance is mostly irrelevant for the loads found in a domestic dwelling. However with a solar inverter you presumably want to actually use a majority of the energy being created, and if you only connect a single phase to the property loads you will only be able to use about a third of the...
  11. flameport

    Cable size and diversity

    Then there is the question of what is meant by this mythical 'signing off' process.
  12. flameport

    What fire rated downlights are you all fitting?

    Not true, and no one cares about EPCs anyway, they are just a thing people are compelled to get when selling a house. They are also grossly inaccurate and only cover certain items that the software knows about.
  13. flameport

    What fire rated downlights are you all fitting?

    Never noticed or cared. It's a metal plate with a hole, a glass disc, a couple of springs and a GU10 lamp holder. Warranty not required.
  14. flameport

    Armoured cable sizing

    Junction boxes and other connectors are sized on the cross sectional area of the individual conductors. The diameter of the outer covering of a cable is unrelated.
  15. flameport

    What fire rated downlights are you all fitting?

    https://www.toolstation.com/integral-led-evofire-fire-rated-downlight-85mm/p58865 with whatever GU10 lamps are desired. Sealed affairs are a fail. Seen far too many from various manufacturers where they have failed after a year or two, exact replacements don't exist, manufacturers warranty...
  16. flameport

    BT phone line/service 'upgrade'

    They certainly did, as in a certain block of flats near here which has FTTP and those exact ONTs from when it was built around 7 years ago. However they have already been abandoned - the battery part still works if people can be bothered to put batteries in it, but when broadband service is...
  17. flameport

    BT phone line/service 'upgrade'

    Correct. There are no new copper PSTN services, they have been unavailable for over 2 years, the last orders for such things were in 2023. Those people that already have one and also have ADSL / VDSL or some other broadband product delivered over copper are already being migrated to VoIP...
  18. flameport

    Two 2.5mmT&E to a garage?

    An unusual choice but could still be compliant. A 32A circuit presumably? Nonsense. With thinking like that, nothing would ever be installed anywhere.
  19. flameport

    Shepherds hut electrics

    It won't be. iv - All the circuits will comply with disconnection times (if not then there are severe problems which no amount of supplementary bonding will fix) v - All the circuits have RCD protection (from the RCBOs) vi - It's a hut, extraneous parts not found unless for some inexplicable...
  20. flameport

    12V spotlight for bathroom

    Get a 230V AC one and dispose of the transformer. Vastly more selection available. 12V affairs are basically obsolete, being primarily designed for halogen lamps.