  1. Z

    connecting 28mm service valves to 22mm pipes

    I am trying to connecting 28mm service valve to 22mm pipe. see pic, the 28mm service valve shown on the blue circle and the 22mm pipe show in the red circle. I am looking for flexi connectors that will give me 22mm compression from one end and 28 female from the other end to connect the pipe to...
  2. Z

    Power devil 3.5 Hp does not keep working

    John, many thanks for your help. took the carburetor apart cleaned all the Jets and the mower works better than before.
  3. Z

    Power devil 3.5 Hp does not keep working

    here is some pics
  4. Z

    Power devil 3.5 Hp does not keep working

    tried this and it does not
  5. Z

    Power devil 3.5 Hp does not keep working

    my Power devil 3.5 Hp petrol mower stats from first pull but stops again after few second. any idea why and how it can be fixed.
  6. Z

    liquid screed is very shallow

    the recommended thickness is 50mm by the provider. all the client can do is follow the provider instructions to prepare the floor as level as they can and leave it to the provider to laser it up and screed. this is what they are paid to do and they are the expert not the client. however, past...
  7. Z

    liquid screed is very shallow

    porcelain floor tiles 10 mm in thickness with 10mm tiles adhesive
  8. Z

    liquid screed is very shallow

    many thanks for your in put guys. UK liquid screed has come back to me and they re assured me that they have at least 40mm in that area. the also said that the screed they provided can work even at 20mm. most importantly they took full responsibility to handle any complains from the building...
  9. Z

    liquid screed is very shallow

    the liquid screed provided by UK liquid screed LTD is very shallow. it was installed on Friday and was told not to check for at least 48 hours. however when I had a look today I noticed the under floor heating pipes of my sitting room are showing in nearly 2 third of the area., see attached...
  10. Z

    lintel over upvc slide door 2100

    woody, many thanks for your time. this is exactly what I am trying to do.
  11. Z

    lintel over upvc slide door 2100

    I am trying to fit upvc slide door in between the door and the boarded window, see pic. the width of the door will be 2100mm. Hence, I need to brick up half of the door and half of the boarded window to make the required space for the door. is there any way I can do that without taking the two...
  12. Z

    PVC door mechanism id not working

    when I lift the door handle, the top and the bottom tongues engage with the frame and the door looks without an issue. however when I open the door, turn the the handle down, only the upper tongue re tracts and the bottom one does not. it only retract partially just about to open the door...
  13. Z

    how to complain or change the building controller

    he said it was not. he is very awkward and heard to talk to giving time as an excuse. the original plan was to put concrete beams and blocks as we did with the extension. however, when I took floor board off there is not much space underneath. if I install the block and beams I end up with...
  14. Z

    how to complain or change the building controller

    my house was built in 1963 on a concrete platform of 300 thickness. I am building an extension and renovating my main house in the same time. both planning permission and building reg was granted Feb. 2019 by my local authorities in the south west. the work has started but due to corvid and...
  15. Z

    what is best floor for underfloor heating

    the downstairs is all tiles as I was able to screed it. but this is the second floor where it is going to be laid joists, therefore, you can not use tiles
  16. Z

    what is best floor for underfloor heating

    I am upgrading my house and have installed under floor heating. what is best floor that is suitable with underfloor heating, is it Laminating real wood bamboo and what thickness
  17. Z

    Worcester boiler 24 CDI, boiler does not fire when there is demand for DHW otherwise it fires up

    Many thanks for the advice, worcester bosch genuine part has been fitted
  18. Z

    Worcester boiler 24 CDI, boiler does not fire when there is demand for DHW otherwise it fires up

    good point, however, I believe most combi boilers work on the same principle when it comes the DHW output. also it is sensor responsibility to to shut the boiler down when the temperature accedes the limit. furthermore, both sensors looks exactly the same , identical
  19. Z

    Worcester boiler 24 CDI, boiler does not fire when there is demand for DHW otherwise it fires up

    I did more test on the boiler today and found out that both the fan and the pump work for a short time then they stop when there is a demand for DHW. this gave me the indication that the microswitch is working and does its job by passing the order to the PCB to fire the boiler However, when...
  20. Z

    Worcester boiler 24 CDI, boiler does not fire when there is demand for DHW otherwise it fires up

    This boiler dose not fire up when there is a demand for DHW, but the it fires up when there is a demand for CH. The diverter valve works ok its head extends when there is a demand for DHW and engages with the microswitch on top of it. Also the pump is working but the boiler does not fire. I also...