  1. sparkymarka

    Wired v wireless

    Just fit a modern alternative….as long as you have the correct amount of cores to the bellbox …4 minimum …5+ better
  2. sparkymarka

    Wired v wireless

    So you was a cheapskate all those years ago and fitted a polypropylene bell cover instead of paying for a polycarbonate one …lol
  3. sparkymarka

    Internal Speaker Volume Levels

    Fit a pyronix twin alert ( speaker and internal sounder ) if you can’t get the correct balance of entry exit and alarm tones from the speaker ….i find the larger speakers too loud on a domestic system …post picture of the speaker you are using at the moment
  4. sparkymarka

    Accenta G4 LCD Panel Issue

    Which ever ….
  5. sparkymarka

    Accenta G4 LCD Panel Issue

    I would remove power from keypad and reconnect it …
  6. sparkymarka

    Smart replacement for a Securit 700L keypad?

    Yes …make sure it’s an elite …
  7. sparkymarka

    Bad Requests (400 Error)

    Getting same on iPhone …ok if I go private browsing …also ok on iPad …?
  8. sparkymarka

    GSM Alarm sensor flashing red light problem.

    Looks like eBay tat unfortunately
  9. sparkymarka

    Smart replacement for a Securit 700L keypad?

    No change both ….. Options ….premier 24 plus keypad and smart com . Not really a diy panel …but app access free Euro 46 plus wifi XA card Bit easier to program App free for first year then £35 after
  10. sparkymarka

    Texecom alarm with SmartCom - ATS path fault, can't access UDL/digi menu

    You only have to remove the one with 4 wires connected as this provides the smartcom power ….worth a go …
  11. sparkymarka

    Honeywell Viper Shock sensor on Texecom Premier LED flashing

    Is it the only device on that zone ….does the alarm set ok ? …if so don’t worry about it …
  12. sparkymarka

    Honeywell SF340J alternative (for Texecom Premier 24)?

    All existing parts should be ok ..
  13. sparkymarka

    Honeywell SF340J alternative (for Texecom Premier 24)?

    You would be better with an elite version as that’s quite old …
  14. sparkymarka

    Honeywell SF340J alternative (for Texecom Premier 24)?

    What software is the premier24 ?press menu 4 on keypad …
  15. sparkymarka

    Honeywell SF340J alternative (for Texecom Premier 24)?

    Had the same issue a few years ago …only thing I could find was….not sure if the 12v one is still available, the 240 one will need mains power but it does have a relay to connect to the alarm
  16. sparkymarka

    ARC call failed Pyronix

    Faraday cage …I’ve had summer houses with foil back plasterboard and the detector would only work if across from the patio windows …
  17. sparkymarka

    ARC call failed Pyronix

    Is kitchen extension new or newer than the main house ? Did they use foil backed plasterboard ?
  18. sparkymarka

    ARC call failed Pyronix

    Kitchen is showing 2 in that screen shot ….how far is kitchen from alarm panel ? Move kitchen pir near control panel see if the issue stops …if so it’s a wireless signal issue
  19. sparkymarka

    Galaxy Flex 50 Notification Options

    Speak to galaxy guy ( self mon )