  1. N

    Which resin for improving rawlplug holes in stone wall?

    I bought some Rawlplug RKEM in the event thermalite im having to screw into wouldn't work but never needed to use it. Few reviews on Youtube for it.
  2. N

    UPVC Window gaps internal

    Hello again 23vc, time to get foaming then! Can tile backer be used as a reveal or do i need to purchase specific stuff for a window as im tiling over them.
  3. N

    UPVC Window gaps internal

    Hi, I have taken this window back to masonry to retile. Original windows were late 90's build and They were added in. Its got some lovely gaps. Do I remove the damp sheet and foam in all around this gap? Do i do this with the bottom as it will need 40mm of tilebacker. I can see why the...
  4. N

    Shimming metal stud walls

    That's fine mate, it's not easy with the variation now days. I'm getting a level ish on the vial when I put the spirit vertically, that vial reading was what worried me. Next worry is should I see any movement after screwing on 20mm Tilebacker (XPS)
  5. N

    Shimming metal stud walls

    Cheers, when you say bonding I take it you mean adhesive bond? This is a metal stud wall though ?
  6. N

    Shimming metal stud walls

    Mate says I can get away with higher runs of tile adhesive with what ive got.
  7. N

    Shimming metal stud walls

    I will be tiling my bathroom with porcelain 600x300's and focusing on the tilebacker at the moment. First Issue is I've got about 5mm out on a plumbline on a first metal stud wall and im sure the rest will be with issues so how to solve? I've thought about shimming with some plastic packers...
  8. N

    Window section im bathroom

    This section has old PB on thermalite and based om the section coming out its wrecked the thermalite. I will be tiling up to the window. In the second picture there is some 30mm gap between thermalite and where they splodged adhesive on before. Im reluctant to remove the PB as it runs around...
  9. N

    Mirror bathroom

    None of these as I've not bought one yet. Had a sparks round and it will go into PL that also feeds the extractor fan overrun.
  10. N

    Concealed piping advice

    Pipe Bending was a flaff but got the nack of it I had a few ripples but nothing to worry about on reviewing. I also went and bought a torch, in reality I really didn't want to worry about fixing compression fitting leaks on an elbow up in my loft and in a channelled bit of thermalite! Using...
  11. N

    Mirror bathroom

    Yes that would be the case. I was thinking about adding a switch live but would I be allowed to add this ? It's just on the Zone 1 and 300mm to the side of the bath/shower zone.
  12. N

    Mirror bathroom

    I will be installing a mirror with light in my bathroom. Not sure what one yet but my plan was run the power off of the last downlight straight through and use On/Off switch on the mirror? With walls not covered yet I've Got the options for wiring at the moment so any help is appreciated.
  13. N

    Channelled too much

    Been looking into what filler. Need 6 to 1 mortar (i think) wetting the blocks. Nothing is supported by this wall other than the gable end.
  14. N

    Channelled too much

    100mm block and 50mm chase
  15. N

    Channelled too much

    It will be tile backer with tiles. I will be filling in gaps with expanding foam.
  16. N

    Channelled too much

    Hi all im slightly concerned that ive chanelled too much thermalite block out. Its about 50mm for a shower valve. The channel on the right side can be filled in as that isnt needed now. Should I be worried and should I fill in with a mortar mix?
  17. N

    Metal wire in thermalite

    Will be London brick on the other side so guess so?
  18. N

    Metal wire in thermalite

    I was channelling out today and came across a thin metal wire. After shtting myself and reminding myself I wasn't on the floor with my hair on end it appeared to be a bit of galvanised metal. Interested to know what this is for if anyone knows or if it was just left there from build.
  19. N

    Bathroom downlight positions...help needed please

    How big is the room OP? Will be doing cutouts for mine in the next few days. Two didn't cut it so I'll be doing a triangle with one just over the bath. I don't get the lights in eyes when in the bath statement, I usually sit upright contemplating life and would rather have light when using...
  20. N

    Bathroom feeds in unvented

    I inherited an unvented system from the previous owner and I am renovating my bathroom with a new shower that will be concealed so I want to get this whole thing done right and when I've got the chance with the best pressures and balanced cold feeds, and then also know when I do my ensuite I...