Search results

  1. D

    wta2000 dryer

    hi, just fixed my dryer with using 'sticks like ****' by glueing the extractor fan back on to the motor shaft. then realised that you could actually buy new fans and clips to secure them (search for bosch wta2000 spares) then learnt that the Bosch wta2000 is actually made by a company...
  2. D

    single pipe upgrade

    hi all, thanks for your help on a previous post which has helped me determine that my house has a single pipe system. i'm fitting new rads throughout and some of the older ones did not get hot (possibly they were on the end of the ring) and want some advice about this please. 1) having...
  3. D

    radiator query

    hi guys, in the middle of a big renovation of my house and fitting new trendy rads but have a strange issue. i've seen this when replacing radiators downstairs and wondered about it then but now its got me confused. there are two pipes going to the rad as usual; supply and return but...
  4. D

    essex flange

    hi im replumbing the way the water flows to the shower pump as its installed incorrectly. the cold supply to the cylinder has a tee in it to supply the cold input to the pump which causes lower pressure at the hot pump supply. the problem is that the cold storage tank is 'built into the...
  5. D

    water pressure

    any suggestions appreciated! the tank is only half meter above the cylinder and the water presure available at the hot and cold to the pump are a lot different (cold much more). have tested this just by taking off the supplies to the pump one at a time so its not to do with the way its...
  6. D

    fitting essex flange

    can anyone please let me know the best way to slightly drain the hot cylinder to allow me to fit essex flange. do i need a suction pump or is there a secret method which someone can tell me :lol: :lol:
  7. D

    water pressure

    hi guys should the water pressure be much different between the hot tap and the cold tap (normal cold storage feeds cylinder jobbie) :D
  8. D

    emptying cylinder

    hi - whats the best way to empty the cylinder? :D
  9. D

    shower probs

    hi my shower used to work fine (ish) but now it doesn't. :( the system is as follows: 50 gal cold storage and there is a 1 foot head of water above the shower head. the top of the cylinder is 2 feet below the bottom of the cold tank. the water feeds a double ended pump (via 2 gate...
  10. D

    potterton profile 80

    hi newbie here so please go easy with me! my boiler does not fire up correctly. when powered up the normal sequence of events happens; the fan runs ok, the pressure switch operates, the gas valve opens (the gas meter also shows gas usage) but there is no spark. the gas valve seems to click...
Back