    Blanki g cooker isolation under sink to pass EICR

    If I get electrician to oin the cooker cables and blank box off with blanking plate. The circuit is on its own supply with rcd protection. If this is done is this compliant to pass EICR ?
  2. D

    3 port valve right way round ( photo in thread)

    Hello Can anyone advise is this 3 port valve piped correct. B is going to the cylibder is this correct ? Thanks
  3. D

    Sentinel x 400

    I put some Sentinel x400 in a system. I am hoping to go away. If I do not get it out before I go as in a rush. I would have to get it drained and flushed when back. This could mean it has been left in for 5 1/2 weeks. Could I incur any problems by leaving in for such a short period longer than...
  4. D

    Redland concrete plain black roof tile

    These tiles are they cheap and nasty or OK?
  5. D

    3/4 bsp hose connector - Spiro filter

    Does a 3/4 hose connector like one in image fit to end of a spiro filter drain off ?
  6. D

    Identifying flow and return

    In my picture below have I identified correct for flow and return pipes ? Thanks in advance
  7. D

    Suspected blocked feed t on heat only system

    I suspect I have a blocked feed T on the system. When hot water is heating up there s banging on pipes. The system recently had a drain down to replace a 3 port valve. I do not think the feed was isolated by gate valve or tank bunged and may have pulled sludge in on re fill. Going to check...
  8. D

    Forgot to drill hole for extractor supply cable behind extractor ? (Ed.)

    We forgot to put the feed in for extravtor. I don't fancy removing the tile. If I get a hole drill fir cable behind where ectravtor is going to go. Is thete any tool that could drill wall amd through side of back box to get cable in without breaking the tile ?
  9. D

    Magnaclense

    Looking at buying a magnaclense. Seem some second hand ones on ebay. Question is will a brand new one be alot more effective than second hand. It is only for personal use to flush a microbore system once a year ?
  10. D

    Sentinel x400

    I put central x400 in system 4 weeks today. I flushed out today but have realised I may not of flushed 3 of the down stairs rads as I should of used the drain offs on the downstairs radiator separately. I would of got most out but may of left a little in. I can't get it flushed again but...
  11. D

    Magnaclense

    Looking at buying a magnaclense to clean a microbore system and maintain it. I have a Fernox tf1 ( black) filter on the system. How can I connect the magnaclense without the magnifier. Can I connect it with a adapter to the radiator valves if I remove a radiator ?
  12. D

    Tile around freestanding bath waste

    How would you best tile around this waste ?
  13. D

    32 mm compression on 35mm chrome

    Will 32mm compression fit onto 35mm chrome pipe ?
  14. D

    Trap connection problem

    I have a crome bath waste and have been trying to connect a 40mm hepvo waste trap to it but it's way to big. Tried a 32m which could not go on. I measure the crome end and it's 35mm. How do I get a trap to connect to this secure ?
  15. D

    Shower and batb waste

    If got a shower and bath in. And waste needs re doing out wall into grid. Is it better to have shower and bath on separate runs into a hopper ?
  16. D

    Wall tiles on bath platform

    We have selected a tile for round bath and would like the same tile for the area where bath is on a platform. Would it be OK to use the wall tile just on the bath platform.? They are only small tile like brick size
  17. D

    Isolation valve into flexi

    Is it OK to put a isolation valve directly into this end of flexi hose ?
  18. D

    Backerboard

    A platform has been built in my bathroom to put freestanding bath on. This platform has been plyboard with 18mm plyboard. Prior to tiling would it be best to cover the plyboard with backerboard. Thanks
  19. D

    Freestanding bath trap

    I have a freestanding bath with a crome trap. I have attached a image of instructions . If I use installation method A. A blank cap goes on bottom of the trap then the water can run straight out wall into a hopper. But my question is if done this way the u bend does not get added to...
  20. D

    Freestanding bath install cost

    Hi. Just a question . Do freestamding baths cost more to install than a normal ? Thanks