Search results

  1. Agile

    Oil dilution problems on Focus 2017 Mk 3.5 1.5 litre durotorq 120 bhp engine

    My friend tookhisFord to the main dealer for a free DPF software upgrade> He had also agreed to a £190 but unspecified diagnostic check! Well nothing was discovered on the dignostic test and they did not make any charge. And the test was done by a 30 y.o. female. He thinks it may have only...
  2. Agile

    Mini inspection chamber extension.

    Maybe you need to consider who fitted it and how long ago. It is only a small amount outside the specifications and not something that I would expect would upset anyone. The regulations are written to be complied with but there are no drainage police going round with flashing blue lights about...
  3. Agile

    Oil dilution problems on Focus 2017 Mk 3.5 1.5 litre durotorq 120 bhp engine

    His Ford Focus does use the DPF cleansing system but he does not know when it does the regeneration. I thought it might give an indication. He does about 80% of his mileage on motorways so I would not expect the DPF to get very blocked. His engine has only done 66,000 miles. There is a...
  4. Agile

    Oil dilution problems on Focus 2017 Mk 3.5 1.5 litre durotorq 120 bhp engine

    A friend of mine has this problem on his car. He thinks it is a common problem on his model. He thinks that it is related to the car's automatic procedure for cleaning the particulate filter! But I am rather sceptical about this as there seems to be little information available on the...
  5. Agile

    Pump wrong way around

    So when it is running which pipe at the boiler is hottest? The flow at the top or the return at the bottom?
  6. Agile

    Boiler Service cost - unresonabley high? Conflicted.

    Normally described on boilers as an irregular rapid knocking noise. Usually caused by calcium deposits within the main heat exchanger. Most common on older boilers with cast iron heat exchangers. Usually easy to cure with the right chemicals and a little experience.
  7. Agile

    Big pressure swing - 1 to 3.4 bar on Vaillant Boiler

    I do not recommend that as it can get forgotten and complicate anyone coming to deal with it correctly. But it does work for anyone without a compressor. But then I always carry a compressor with me. In practice boiler PRVs rarely get checked. But they are pretty reliable and usually do...
  8. Agile

    Baxi 105e: Plate heat exchanger - can this be cleaned?

    I would use hydrochloric acid at about 7% for cleaning plates. Usually using two applications of the acid. Sometimes warming it up to about 30 C and particularly moving it around quite a lot.
  9. Agile

    Immersion failing

    My way of thinking is that it is likely to be an electrolytic action. This can often be caused by faulty wiring causing currents in earth wires. My first check would be with a clamp on ammeter on earth connections around the plumbing.
  10. Agile

    Changed radiator now F&E Tank is overflowing

    Alls well that ends well! But I don't understand your original reluctance to go and have a look in the loft. Nasty cold dark places I know but all the evidence pointed to a problem up there!
  11. Agile

    Changed radiator now F&E Tank is overflowing

    When cold what is the depth of water in the header tank? Only needs to be about 100 mm. But when hot expansion increases that to about 200mm.
  12. Agile

    Radiators : Toolstation / Screwfix

    I used to like the Screwfix Kudox rads which are made in Turkey and seemed quite solid.
  13. Agile

    Vaillant EcoTec810 plus Heating Not Working

    You would need to see if the diverter valve is moving when the hot water tap is turned on.
  14. Agile

    Big pressure swing - 1 to 3.4 bar on Vaillant Boiler

    It is serious from the boiler's point of view. If the PRV was operating then the system pressure would probably fall below the minimum needed on start and stop the boiler from starting up. In reality the EXV { expansion vessel } probably only needs a few strokes of a foot pump to add a...
  15. Agile

    Big pressure swing - 1 to 3.4 bar on Vaillant Boiler

    I would expect any competent service engineer to ask questions about the pressure to see if it needs further investigation.
  16. Agile

    Boiler Service cost - unresonabley high? Conflicted.

    Unfortunately there are a lot of different views on what to do on a service. As a minimum remove the cover inspect carefully inside for leaks or other problems, Check the burner pressure or gas consumption. That might take 30 minutes on site so £60 to £90 perhaps. These things are slewed by...
  17. Agile

    Hot water secondary return help

    For myself I would make it very simple with just one connection at the effective furthest HW point from the cylinder. I would also time it and use a thermostat to turn off the pump when the return from it became just warm.
  18. Agile

    Third world travel forums?

    And so did I. But it was after being on secondment from the BBC to Qatar Television that I decided to drive back to the UK from Doha. I allowed 30 days although some people driving long hours did it in just 10 days. I made it into a holiday and took about 14 days.
  19. Agile

    Hot water secondary return help

    Most secondary returns are just done in 15mm as it only needs to be able to create a small flow to keep the hot water circulating a very small amount. Obviously quite a lot of lagging is required on the hot water pipes which is something which is not always done in this country. Just as a...
  20. Agile

    Heating System Design - Storage Combi?

    Government policies and gas supplies may be quite unstable over the next few years. So my strong advice would be to keep the existing for a few years and avoid wasting money buying something which may not be the best solution in a few years time.