Search results

  1. F

    fault finding

    evening. new to breakdowns but seem tobe doing ok for some reason. i got called to ideal wf2000. fan running no ignition. checked aps that was fine. after potterting around i disconnected h/t lead on b oard reconnected and hay presto spark , pilot ,main burner!! fixed. however im curious...
  2. F

    removing airlock hot pipe

    hello. i was wondering when wanting to clear airlock from hot pipe its all great when the kitchen sink as 2 seperate taps which the hose can fit on to. however to avoid linking cold supply and hot supply connectors on washing machines, under sinks etc is there some rubber adapter on the market...
  3. F

    manufactures jobs

    nope. we go find the fault if the boiler if boiler needs new part then its the engineer who fits part and results in boiler up and running. i get other engineers diagnosis, go and fit part and boiler works. great. but when youve fitted a part and it doesnt work youve just waisted your time...
  4. F

    manufactures jobs

    what do you care kirk gas. get a life!!!weirdo
  5. F

    manufactures jobs

    hello. couild anyone tell me anything about working for manufactures? any particualr name is best to work for? i suspect they advertise via agencys, know the name? what kind of salrys in london? 9-5, no call outs? seems like great way to get experience and have normal 9-5 whilst doing private...
  6. F

    change syncron motor

    standard syncron motor on honeywell mid valve. what is best way to change these motors? disconnect wires from the motor itself and replace with new motor or replace motor with new motor and its associate wires?
  7. F

    transco employment

    can get called in on rest day with no extra??? if thats the case who would work for them?
  8. F

    transco employment

    Would like some advice on working for transco emergency engineer in london. I was talking to one of their guys and he says he works 5 days on 5 days off for 35k . just wondering about if anyone has any experience with them apart from caping meters off, changing handles, meters, regulators etc...
  9. F

    flue analyzer course

    does anyone know of a flue ana' course? surprised no manufaucters like kane dont do it. looked in installer mag and nothing
  10. F

    pump vent

    hi . is it ok to remove the pump vent on any pump? i assume if removed and water does come out then its knackered, otherwise its ok to remove?
  11. F

    hot water

    hi. s plan system 2x2 honeywell port. to get hotwater have to put on heating. only possibilites is piping wrong , programmer wiring?? thanks
  12. F

    cp12

    need some advice on pricing? i am thinking of approaching some firms and offering to do their landlord certificates on weekends as extra cash as i know two local firms that have a back log on their cp12's. im based in london and assuming properties located close together i m thinking of £20 a...
  13. F

    boiler stat

    hi. could anyway tell me how to know if a boiler stat is miscalibrated ?measuring flow temps with thermometer?? thanks
  14. F

    switch live

    hello. could someone explain to me if a switch live is dead into a suprima then its a faulty external controller ie m/valve,stat,programmer??m ta
  15. F

    hot water issues

    thanks for prompt reply. whats the hot water rubber diaphram?? what other stuff can cause poor hot water temp? thanks
  16. F

    hot water issues

    just moved into the world of combi fault finding and wouold like some advice on poorm hot water performance please. main causes of poor hot water performance== diverter letting by into heating system, lime scale in plate exchangers , faulty or scaled thermistors, incorrect gas settings/supply...