Search results

  1. W

    B&Q kitchen gloss white clad on end panels align door to cornice or panel front edge?

    Hi, I’m fitting a B&Q Santini / Gloss white slab kitchen, I have matching clad on end panels for the wall and base units. This is more in regard to the wall units as I have the 790mm type clad on panels that stick protrude above and below the wall cabinet so that you don’t have to mitre the...
  2. W

    Non-Barrier Pipe, New boiler, Stainless or Cast Aluminum Hex

    Having a new boiler fitted to replace my old cast iron Ideal, I have non-barrier plastic Hep so am expecting to have system corrosion caused by the oxygen infusion. To minimize problems with the boiler should I go for a boiler with a stainless steel or cast aluminum heat exchanger? Looking at...
  3. W

    What is my boiler doing? Please Watch Video

    Does this after it ignites:- (Not everytime on ignition but you can certainly hear it when it's doing it.) [/youtube] http://www.youtube.com/watch?v=jqHwwv06d9Q You are seeing the burner through the sight glass, It's an Ideal Classic RS40, Serviced just last week. I think its trying...
  4. W

    Ideal Classic RS40 "Woofing noises" and Yellow&quo

    Hi, Just had my Classic RS40 boiler serviced as I was concerned about yellow in the flames, noisy combustion (rattling the casing) and a "woofing noise" - sounds as if some of the flames on the burner are being blown out. After the service, cleaning of the heat exchanger, burner, gas...
  5. W

    Hydronic Kick Space Fan Heater Removal

    Hi, My system is 12 years old, open vented, pumped y plan, ideal RS40 boiler, house has solid floor downstairs so rads are all on 10mm plastic microbore, fan heater on 15mm plastic. I have a myson kickspace 500 hydronic fan heater in my kitchen and I am looking to remove it and just need to...
  6. W

    Ideal Classic RS40 Shhhhhh... cycle shut off noise

    I have just moved into a house with an 12 year old Ideal Classic RS40, it appears to be working fine but when the boiler cycles on its stat it makes aloud shhhhhh noise before it clicks off and returns to pilot. The length of the shhhhh noise varies from time to time but can be a for a few...
  7. W

    Circulation pump replacement questions.

    I have a couple of questions that I would like help with please, My circulation pump has failed, it failed to kick in one morning causing the boiler to wake me up! I cant manage to open the pump bleed screw to see what has happened, (tried turning in the direction of the arrow) but it wont...
Back
Top