Search results

  1. I

    Isolating water (mains unvented system)

    hi there, I need to change a shower mixer (aqualisa hydramax/colt) in my daughters flat which is easy enough, however I just need an idea of how to isolate the hot/cold supplies so I can do it. It is a 12 year old Barratt flat with hot water cylinder tank in the airing cupboard and expansion...
  2. I

    Glow worm fan replacement - seal?

    I have a GlowWorm boiler, a fuel saver F model 100F which is around 1989 vintage and is fine apart from a noisy fan. My local Gas Safe man checked with his usual supplier and the fan is obsolete but he did say if I found one he would fit it as part of the next service. I have bought and...
  3. I

    Wiring in Texecom Odyssey 3 bellbox to look like live

    Hi there, I have just bought a 1988 house that requires renovation, it has a hardwired and powered down/redundant 1988 alarm system. I have a new Odyssey 3 external sounder and what I want to do as a temporary measure, while I work in the house, is to remove the old sounder, wire in the new...
  4. I

    Adding UFH to new conservatory-tee off boiler before pump?

    Hi there, a question for you... I have a 1972 house with an open vented heating system as follows: In loft: cold water tank and heating vent cold water tank Upstairs landing airing cupboard: hot water cylinder, pump, 3 way motorised valve (Y plan), drayton wiring centre Upstairs landing...
  5. I

    Worcester oil boiler (camray utility) - need permanant live?

    I have a 17 year old oil boiler which I am getting replaced. The boiler is a heating only boiler in my utility room with the 3 way motorised valve/water cylinder/pump in the airing cupboard and water tank/heating water system tank in the loft (i.e.vented). I have a Honeywell programmer and...
  6. I

    Intellisense alarm - using alarm with a PIR removed

    1) Hi there, I have an Intellisense alarm and due to moving a wall have removed the zone 4 (kitchen) PIR. I opened the PIR (Rokonet Cosmos PQ), typred in my code to stop the tamper alarm, joined the tamper cables and disconnected the alarm and power cables from that PIR. It will be a few...
  7. I

    Scantronic 9448+ tamper alarm (with tamper linked out)

    Hi there, in July 2008 I had an intermittent problem with my 9448+ where the tamper alarm would trigger (with the alarm set or not set). As I was going away on holiday I did the following: 1) replaced the battery with a Yucel one from my local alarm supplier 2) linked the global tamper...
  8. I

    Split load CU - cooker and immersion RCD protected?

    I know this has come up before, but I was hoping to establish definitively whether a 3kW immersion heater (20 A MCB) and a 4 year old electric cooker (10.8Kw, 40 A MCB) should be RCD protected or not when I get my old CU replaced with a new split load one thanks!
  9. I

    Simple bonding question post new plumbing...

    I had a new bathroom installed a short while ago, and a sparky did all the bonding. It seems all OK, basically I have 10mm cable to the stopcock (no gas in the house), and in the bathroom itself I have 4mm cable from the shaver socket earth (fed from the lighting circuit) to the cistern...
  10. I

    Are Wylex consumer units any good?

    I need to get my old rewirable fuse unit changed, however due to space constraints (pipework either side) and the desire to have a split load unit I am struggling to get a new one that fits. Screwfix sell a Wylex 9 way unit which will just fit in the space, however are Wylex units OK...
  11. I

    Bathroom bonding Q - light and shaver socket

    I have just moved into a house and have had a good look around at the bathroom bonding. All the pipes (bath, basin, central heating) are all nicely bonded together, as are the pipes in the airing cupboard which also houses a whole house pump. However..... I notice the bathroom light ( a...
  12. I

    Fitting Bathroom shaver socket into s/steel cabinet

    I want to fit a stainless steel corner mirror cabinet into my bathroom but want to fit a surface mount isolated shaver socket inside the cabinet just si it is neat and out of sight. The bathroom earthing and electrics are all up to standard, but the question I have is is it advisable to earth...
  13. I

    Question about recently fitted split load consumer unit

    On Saturday morning I had a split load consumer unit fitted. The electrician found that the consumer unit supplied by his supplier was incorrect and not a true split load unit. He could not source what he wanted but said no problem he could use the one he had (RCD non split load one). What he...