  1. Blooflame

    Baxi Duo Tec 40 HE A Fluctuating Hot Water Temperature

    I'd love to help but am amazed that the responses just go on..and on...and on. Lime you say...too much theory.
  2. Blooflame

    BOILER COVER UK

    Actually no. They paid me for one job but since then there has been nothing. Everything was covered by emails (costs before buying parts plus labour). They gave the go ahead. So with that in mind I felt covered legally and I think I am. it's just the boll**k ache chasing around. I clearly won't...
  3. Blooflame

    BOILER COVER UK

    I was recently contacted by Boiler Cover UK (via GSR) and was asked if I would like to undertake occasional work for them. The staff were and still are personable so no problems there. To cut a long story short they owe me in the region of £900. To date I've had £115. I was informed that payment...
  4. Blooflame

    Boiler pressure keeps rising.

    You have to keep the prv open whilst you pump this up
  5. Blooflame

    Heatline C24

    Thanks for the heads up on where to get the manual. The basics barring the gas rate were done baz, I do do the basics a blocked filter where ever will give such a problem. The tap is not the issue, like I said the cold to that tap was ..isolated...
  6. Blooflame

    Heatline C24

    Tony please mate, i can't find the bleeding place so ease up, no one should be bawled out in public...I'll find it thanx
  7. Blooflame

    Heatline C24

    Chantelle, as I've already mentioned, the cw to the bath was isolated so it can't be drawing through there. As I've already mentioned ...again...I'm GSR and once again...there is no manual. That's why I'm here, in case one of my peers can Assist me, as most of us have over the years in here.
  8. Blooflame

    Heatline C24

    Thanks Baz, I haven't gas rated it but I did increase B.P. as it was about 4mb. The problem only seems to be with the bath mate. the dhw pipe just goes very cool
  9. Blooflame

    Heatline C24

    I'm Gas Safe Registered. Been to a Heatline C24 to investigate Luke warm DHW. It seems ok at the sinks (kitchen and bathroom), but from the bath the DHW pipe at the CHB goes very cool indeed. I've isolated the Bath Cold water but the same thing occurred so I'm presuming the mixer is ok...
  10. Blooflame

    Worcester Combi - 2 issues

    Well technically Gasright may have a point, however it's not what you say it's how you say it. That said I'd wager Mattensteins diagnosis is right. I left BG last year (phew!). There has been a constant issue from engineers about installs. One bloke can't powerflush a system and fit a boiler in...
  11. Blooflame

    Are you anywhere near Plymouth?

    Are you anywhere near Plymouth?
  12. Blooflame

    Glow Worm 30SXi Problem

    Absolutely nothing to do with a gasket. The expansion vessel requires air to be pumped into it. Half the time and cost of a gasket set. It seems the incompetents are taking you for a ride mate.
  13. Blooflame

    Landlord wants me to pay bill for investigation of gas leak

    The landlord is responsible legally, you have the best intentions there's no way on this earth you would pay. Tell him / her to take you to court...they won't. If he starts bullying you then take him to court
  14. Blooflame

    Biasi DHW diaphram

    Tony, it's the pump flow switch
  15. Blooflame

    Modena 102

    yep, disconnected lead,tried that but it doesn't respond to adjustment (perhaps my answer is there).
  16. Blooflame

    Modena 102

    Took alook at a Ferroli Modena 102 which kept cycling. Both sensors were around 15k (ohms) after some use so expected them to be lower. I also discovered that on both heat and DHW there was no modulation. Got the sensors and replaced but [no] surprise same issue. I can't decide on whether it's...
  17. Blooflame

    hdb854d e07 code

    Thank you mate. Already been back and changed for another model. having a SMEG, to a Gas man it's all Greek, dunno if thats good or bad
  18. Blooflame

    hdb854d e07 code

    Hi. Recently had this replacement appliance from Currys. The first one was doing exactly the same thing. 1) Absolutely goes berserk on the spin, so much so I turned it off for fear of destroying my new Kitchen. Doing the wash is ok (until the spin). 2) Doing the drying cycle gives us the...
  19. Blooflame

    Ariston Microgenus 27 mffi no ignition - fan not running

    started from zero 2 months ago...absolutely no clients as I never did private jobs. Had magnetic cards made on vistaprint, knocked doors and pitched my story about starting up and would they keep the card. Had quite a bit but not as much as I'd like. That said been out to a breakdown this...