    VAILLANT TURBOMAX VUW 282E WATER NOT HOT ENOUGH.

    WENT TO A JOB 2 WEEKS AGO & TRACED FAULTS TO NO CHARGE IN EXP VESSEL & SEIZED DIVERTER VALVE . FITTED OVERHAUL KIT & PUMPED UP VESSEL. all was ok. today cust phoned & said hot water not getting as hot as it used to. on checking boiler it seems that it is shutting down before the dhw is up to...
  2. E

    ultracom sxi f9 fault.

    been to a 30 sxi today f9 fault. book o words says loose conns, iffy pump or faulty pressure sensor. boiler display says 2.4 bar system pressure. seperate pressure gauge reads the same. if i disconnect sensor conn then boiler display says 0 bar. when i re-connect it goes back to 2.4 bar. pump...
  3. E

    glow worm ultimate staying on with s/l disconnected !

    :?: had an ultimate 50ff which hadn't been used during the summer so the pilot jet was blocked. also heating hadn't worked for ages (bloke lives on his own & spends all spare time in pub i think.) cleaned pilot jet, replaced seized & corroded mid pos. turned boiler on for safety checks etc &...
  4. E

    AIDS? - come to Britian.

    exterminate them & re-enforce our borders (ports) with machine guns & watch towers
  5. E

    chaffoteaux flexiflue problem very weird

    boilerman2. just re-read your reply (thanks by the way) & don't understand one part. when you say the aps will drop out on idle & cause pilot outage, then what does the aps do? i thought it made on hi speed & went back to rest mode at low speed fan (idle)
  6. E

    chaffoteaux flexiflue problem very weird

    happens with the case off so not lack of air although i will check the flue anyway. just cant work out why fan is on full speed at rest & goes to slow when microswitch makes when the tap is turned on. have checked all wiring connections & all are as wiring diagram on boiler casing.
  7. E

    chaffoteaux flexiflue problem very weird

    am having a nightmare with a flexiflue. last month i replaced the pcb as it had burnt out. got a recon one from allspares in wembley. all was ok. got another call last week. the fan had seized & the cooling ring had come loose on the shaft. fitted a new fan. now the weird bit. the t/c would...
  8. E

    worcester junior 24i h/w ok but noise when c/h used

    hot water fine but when heating switched on, loud banging & eventually lockout. pressure 1 bar. any pointers please? (pre condensing model)
  9. E

    another baxi combi 80 instant whining

    i am a gas safe engineer with 21 years experience but i am not the oracle & if i need help i ask. is that strange ?
  10. E

    How To Get To Reset Switch On G.W. 30CXI

    i may be wrong but i thought the o/heat reset is inside the inner boiler cover up on the top l/h side at the back. (i know the british gas 330 which is a glow worm is in that place) personally i would have a mk1 3 litre consul GT !
  11. E

    another baxi combi 80 instant whining

    i have the above boiler in a flat i let & the tennant complained about whining noises. i've had a listen & it happens after a hot water draw-off. goes on for about 2 mins & then peters out slowly. the fan is fine as is the pump. magnaclean fitted & a recent boiler off the wall to replace that...
  12. E

    Baxi boiler - Replacing Expansion Vessel

    IF IT'S AN INSTANT (FITTED WITH A PRE HEAT FUNCTION) you can't fit an external pressure vessel as the one fitted has 2 water connections to it.
  13. E

    Best replacement for Ideal Mexico 2 boiler?

    dont forget the ideal classic he. they are still a great common sense boiler without all this zero governor rubbish & only 1 pcb. will last for years. fitted one in my own house !
  14. E

    keston (ugh) fault, b26 but open vented

    :?: serviced a c40 keston friday. usual warped electrode ! all working ok as i finished, customer phoned me up today & said boiler stopped working & shows a B26 fault. this is low water pressure fault. as this is an open vented system, how can that happen,