  1. A

    Connect gas bottle to Weber Traveller

    The bbq has a regulator in it. The Weber pipe is just a patio gas connector to EN417. Do you mean its an option to purchase that pipe, remove the patio gas connector and replace it with a orange propane bottle fitting?
  2. A

    Connect gas bottle to Weber Traveller

    Weber make a connector pipe to connect patio gas to their Traveller series bbq, here: https://www.wowbbq.co.uk/categories/weber-spares/product/weber-adapter-kit/8482~8482 Is it possible to buy a version of that which connects to a standard orange propane bottle instead of patio gas?
  3. A

    Earth bonding after boiler move

    Thanks for all the explanations folks. Very educational!
  4. A

    Earth bonding after boiler move

    OK so if I've understood correctly bearing in mind I'm just a paranoid homeowner. Faulty earthed device with live metal case, I touch it and also touch unearthed CH loop, the electric flows to earth through the earthed faulty device Faulty earthed device with live metal case, I touch it and...
  5. A

    Earth bonding after boiler move

    Given we don't know what is happening under the floor boards. If I imagine a scenario where the currently unearthed CH loop pipework could be touching other copper that is earthed such as the cold feed to the bathroom, possibly an intermittant touching based for some reason like floor flexing...
  6. A

    Earth bonding after boiler move

    Thanks for the explanation.
  7. A

    Earth bonding after boiler move

    Forgot to mention that, yes its copper for first couple of metres until its in the floor void.
  8. A

    Earth bonding after boiler move

    Recenty had a boiler moved. In the old location there was earth bonding to the pipes. After the move there is a few metres of plastic pipe seperating the boiler and the central heating feed and return. So the situation now is the central heating throughout the house has no bonding. Should the...
  9. A

    Stacks removed but gallows and gathered flue remain in loft, can it be removed?

    Thanks for reply. From what I can tell the walls below were bricked up with the bricks from the removed breast and there is also the long L shaped galv ties about 1mtr long put in on 1st floor joists and cieling joists, but there are no long ties from the remnants of the chimney onto the roof...
  10. A

    Stacks removed but gallows and gathered flue remain in loft, can it be removed?

    Got an end terrace that had chimneys removed at some point in history, then at a later time but still some years ago, the stacks were removed but the gallows and most of the gathered flue was left in the loft space. The top 4 or 5 course on the remaining flue are really unstable, the mortar has...
  11. A

    Using 13amp switch box thing for shed

    So I'm using the method shown in Fig. 2 on that IET pdf. It doesn't say what cable to use, can you use standard twin and earth if its in a conduit? I'm intending to use it for an orbital sander and a palm router... if that affects things.
  12. A

    Using 13amp switch box thing for shed

    Thanks! The circuit is on an 80amp 30mA RCD switch in the consumer unit. Gap between house and shed is about 2 inch. The wire that feeds the current security light is using those cable clip things nailed into the mortar. How is it supposed to be done, in a metal conduit?
  13. A

    Using 13amp switch box thing for shed

    The outbuildings article link in the wiki goes to a page not found :( We have a surface mounted pattress box thing with a switch on it and a 13amp fuse in it. Its on the upstairs ring main. It currently feeds an outdoor security light. Can i use this to feed a light and a plug socket in the...
  14. A

    Improving loft insulation with kingspan in rafters

    Ok. Attach some 4x2's on rafters to make a deeper space and make sure theres a good air gap between the kingspan and the roof? So dont need to be changing ridge tiles for summat that allows airflow?
  15. A

    Improving loft insulation with kingspan in rafters

    Hi, Is it OK to stick Kingspan or similar in the rafters and between hangers to improve insulation in loft? It's an 1890s terrace, 4 massive perlins going from gable end to party wall and the rafters aren't that deep. Hangers coming off the lower perlins to the ceiling joists. It's then got...
  16. A

    Swapping pendants for recessed GU10 in hallway

    Have lifted the floor in the hallway but not the bathroom (that fitting is directly under the bath). They are on the joists so the holes will be offset from the current rose positions, but I'm not worried about that because its being redecorated anyway.
  17. A

    Swapping pendants for recessed GU10 in hallway

    Thanks for answers, ive changed the broken link for a picture of the diagram. Above one of the lights is the upstairs hallway, above the other is the bathroom floor - is that a problem for IP rating on the fixture?
  18. A

    Swapping pendants for recessed GU10 in hallway

    Hi Is it OK to swap out the pendent lights in my hallway for GU10 recessed LED using these connectors - http://www.toolstation.com/shop/Lighting/d220/Interior+Lights/sd3066/Lampholder+GU10+240V/p34667 There are two pendants I'm wanting replaced. The current wiring setup in the pendant roses...
  19. A

    Empty water tank

    Hi, sorry this is probably a dumb question, I looked around the Wiki but couldnt find any info. I have just moved into a new house which has a baxi bermuda 552 back boiler system, however, the water tanks have been drained and I dont know how to refill them. The system was checked for...