Search results

  1. M

    Reducing flow from a shower pump

    I've got a 2 Bar shower pump (Salamander CT75 XTRA) connected to a thermostatic valve. I've been having a problem where the pump would start then stop - it could be restarted by turning the temp fully low and then kept running by slowly increasing the temp. Salamander tech support had me do a...
  2. M

    Improve water pressure by raising cold water tank?

    We have a cold water tank in the loft, sat on the rafters. Water pressure upstairs isn't great as the head is probably les than 6 feet. I'd like to improve the water pressure in the upstairs bathroom, and fit a shower without having to install a pump. Could I increase water pressure by...
  3. M

    Faulty 3-way valve?

    Thanks for the replies guys. Can't say whether it ever worked correctly - we bought the house last year and noticed a problem with the rads coming on when the hot water was on. Had the 3-way valve replaced (the whole thing) in October and of course the heating has been on ever since ...
  4. M

    Faulty 3-way valve?

    Hi Guys Had the three-way valve on our heating system changed last year as the heating came on when just hot water was selected. We are now back in the "hot water only" season and the same thing is happening again. Have checked the valve and the selector is moving correctly when I...
  5. M

    Cutting an existing laminate floor at doorway

    Hi Guys Currently have a laminate floor which goes from the dining area through an archway into the kitchen. Planning to replace the kitchen floor with stone tiles. The challenge is how to cut the existing laminate floor where it goes through the archway (the boards are laid perpendicular...
  6. M

    Changing from cooker to separate hob and oven

    Hi Guys Refitting the kitchen and changing from a standalone cooker to separate hob and oven. Have a cooker power point in place with a single switch / outlet for the cooker. The hob will where the cooker is now, so no problem there. The oven will be the other side of the (small) kitchen...
  7. M

    Danesmoor 15/19 Boiler Lockout

    Everything is still working just fine - so far so good! :D
  8. M

    Does monobloc mixer tap need a check valve?

    Hi Guys Was plumbing in the monobloc mixer tap on a new bathroom basin. Connected up the cold feed, thought I'd turn on the tap to see if it worked before I connected up the hot - and was surprised to get a lap full of water from the (not yet connected) hot pipe (the hot tap was "on")...
  9. M

    What connectors for monobloc tap tails?

    Thanks - after posting I managed to find a compression fitting (on one end of an unused TRV) and it is indeed one of those ......
  10. M

    What connectors for monobloc tap tails?

    Have just installed a new monobloc tap with flexible tap tails. At the end of the tail is a female fitiing which looks like it's 3/4 inch (could be 22mm) and a rubber seal inside. Could anyone let me know what type of fitting this connects to? Does it screw on to one end of a compression...
  11. M

    Adding cavity wall insulation to already insulated wall

    We have recently moved to a new house and are discovering for the first time the joys of oil-fired central heating. The main house was built in 1976, so is cavity wall but almost certainly has no cavity wall insulation. We plan to get that insulated at some point using polystyrene beads...
  12. M

    Danesmoor 15/19 Boiler Lockout

    Capacitor replaced, all working OK now. We'll have to wait and see whether it's a permanent fix or "false hope" ......
  13. M

    Danesmoor 15/19 Boiler Lockout

    Thanks. Solenoid didn't do the trick, so capacitor is next on the list. At that point I will give up and get someone who knows what they are doing ....
  14. M

    Danesmoor 15/19 Boiler Lockout

    Thanks guys. I'll blow my money on the solenoid then get an engineer in if that doesn't work! :oops:
  15. M

    Danesmoor 15/19 Boiler Lockout

    .... because this is a DIY forum!!
  16. M

    Danesmoor 15/19 Boiler Lockout

    Thanks guys, have ordered a new coil. Was in the room when the boiler locked out this time. It buzzed for a few seconds before locking out (nothing appeared to run) - is that consistent with a solenoid coil fault? Thanks
  17. M

    Danesmoor 15/19 Boiler Lockout

    Thanks - what should the resistance be?
  18. M

    Danesmoor 15/19 Boiler Lockout

    Hi Guys We have an elderly Worcester Danesmoor 15/19 oil fired boiler in our new house. Had the boiler serviced recently, no problems reported. Boiler has recently started locking out. It runs fine for an hour or so then locks out. Once reset it runs fine again. Photocell is clean...
Back