Search results

  1. L

    Floating floor repair..

    Hello, I have a floating floor in my downstairs toilet area which due to a small water leak that remained undetected has damaged a section of the floor to the point i now have a hole that is about 2ft x 3 ft wide. Underneath the flooring is polystyrene blocks so there is no joists in which to...
  2. L

    Whole house pump

    Hello, I have a gravity fed water system that feeds two shower heads from a tank in my loft. Hot water feed for the showers is fed from regular indirect hot water cylinder that is heated using a regular gas boiler. The water pressure is not great on the showers both cold and hot feeds. The cold...
  3. L

    Vailliant eco TEC plus 430 Heating up when no call

    I have a Vailiant 430 and today for the first time I turned the heating on due to it being cold. I found that after a while the heating was remaining on despite the Nest having been switched off. I went to the boiler and found the radiator symbol flashing which I understand means its active. I...
  4. L

    I-on40 RF Failure

    Hello, Alarm system reporting RF Failure after changing the battery. Tried full power reset still get the same error condition. All Wireless zones show not signal and alarm won't arm due to RF failure. Via HTTP, very slow opening and option selections very slow (2 mins). Was going to try and...
  5. L

    I-on40 RF Jamming

    Hello all, Problem when arming my I-on40 alarm in that several of the Wireless sensors reported RF jamming issues when the alarm was last set. From installation mode I tried to reset one of the shock sensors reporting rf jamming but this did not resolve the issue. In the end I removed the...
  6. L

    XCELRPT PIR Question.

    Just fitted Wireless PIR which is paired up to I-on 40 no issues. After a period of 30 mins the PIR LED stops responding to movement. I seem to recall the PIR stays in self test mode for the first 30 mins of power-up but then goes into normal mode thereafter. Thing is I wasn't aware that normal...
  7. L

    I-on40 Install question

    Hello all, I'm just about to change my TS900 panel with he I-on40 but got some questions. Firstly, access to the web portal how is this possable from the laptop (usb/Ethernet) and if ethernet does it have an RG45 connector? Secondly, can I get access to configure the panel without any special...
  8. L

    BellingIDW604 washing issues.

    Hi there, I've had this dishwasher for a few years now and to be honest it's always be crap at cleaning the plates but recently its got worse. There are no error codes and we always make sure the salt is full and we use a good brand detergent in it. We run through a cleaner every month and...
  9. L

    Menvier TS900 to Honeywell AG6

    I'd like to install a new external alarm box for my TS900 and I've purchased the Honeywell AG6. I'm installing a new external sounder (Honeywell AG6) to menvier TS900, I think the connections should be as follows, can somebody confirm:- TS900 AG6 ==== ====...
  10. L

    Scantronic ts900 & 900 remote

    I have two remote keypads each of which appear to have two zones within the remote keypad but these do not show up within the zone list. Do I have to enable these in any way and if so how is this done? Many thanks...
  11. L

    PowerShower Pump install...

    OK, so here's the problem I have. I have a power shower pump installed (Watermill) which is used to deliver hot/cold to a mixer shower enclosure. The shower enclosure while we don't use them have 6 water jets, monsoon shower head, normal shower head which we do use all of which is controlled...
  12. L

    Ideal Classic 260P

    Hi there, I have enough BTU left in the scope of my boiler and want to add a rad into the same room as the boiler is located in. What I need to know this, is there a min distance from the boiler 22mm pipes flow and return from which you can take the first radiator feed from? Including the...
Back