Search results

  1. A

    Wickes 160 Bar Pressure Washer

    Just had a flyer through the door from Wickes advertising a (upto) 50% off sale. What caught my eye was a 160Bar Pressure washer at half price being sold for £99. Anyone got any experience of wickes own brand stuff, or even better, this particular pressure washer. The only Wickes own...
  2. A

    How do you connect LV under cupboard lights

    Just wondering how you guys do this... I am in the process of installing some under cupboard lights and have so far done the following. I have lifted the boards upstairs and run some 1.5 Twin & Earth through to the top of the cupboard, and also run some between the switch and the cupboard...
  3. A

    Just curious!

    Hi there, I'm curious to know the point of Plastic oval conduit when running cable in a plastered wall. I understand that it is what should be done, but can't really fathom why. A drill bit or an enthusiastically hammered nail is not likely to be stopped by a bit of plastic (or is it?), it...
  4. A

    Soldering End Feed 10mm pipe

    Hi there, I need to replace the radiator in my Kitchen for a much smaller Rad. The pipework is 10mm copper :x that runs down the wall to the centre of the existing Rad. I'm planning on cutting the 2 pipe before they fan out to the valves and run in new pipework to the new valves. This...
  5. A

    Crimps - Help Take 2

    Hi All, Following my previous topic on joining the cable to my Oven isolating switch. TLC have just delivered my nice new Ratchet Crimping tool, some yellow butt crimps for the Red & Black and some blue ones for the earth :D Now please don't shoot me down in flames, I have never...
  6. A

    Crimps - Help

    HI, This is a follow-on from my previous topic on moving a cooker switch. In that topic I asked the best way of joining 6mm 30amp cooker cable (concealed in a partition wall). The answers received was to Crimp the cable (using a proper ratchet crimper). This seemed nice and easy, that...
  7. A

    LV cupboard lights

    Hi there, I need some advice on the best way to install 2 seperate sets of low voltage cupboard lights (in a kitchen). I can either connect then from FCBs, but this would mean having un-light like switches :( Or I could spur them off the light circuit, although this sounds like a major...
  8. A

    Moving a cooker Switch

    Hi, Newbie here, be gentle! I have just put in a new kitchen and have had to move the cooker switch as the old location was too near the Gas Hob! What I have done is this.. removed the existing switch, Run a length of 6mm twin and earth to a new switch - joined these two 6mm...
Back