Search results

  1. G

    Glow Worm Obsolete Boiler Valve Part

    The pilot Injector blocking or electrode lead Shorting out are a problem with the ultimate boilers
  2. G

    transit sliding door switch?

    I have a ford transit and have just noticed what appears to be a broken switch on the frame where the sliding door touches {not the contact switch at the front of the door} it is on the right hand side of the opening can any one tell me what it is for?
  3. G

    Glow worm Flexicom 30cx that displays the F9 fault code.

    Possiblle flat expansion vessel may need recharging,this can give F9 fault.
  4. G

    Valiant ecotec pro 28-problem after install today f61 fault

    Vaillant now do a system turbidity test and put on the report if it is below 200ppm nothing to do with the combustion reading.
  5. G

    Valiant ecotec pro 28-problem after install today f61 fault

    Vaillant now do a system turbidity test and put on the report if it is below 200ppm nothing to do with the combustion reading.
  6. G

    My COmbi boiler - weird fault/query?

    Call out worcester to repair
  7. G

    Vaillant 140 and vrt360f

    You do not need a 140 if you have a 360 it would not work anyway.Personally i would buy a Honeywell prog. roomstat much better in my opinion .
  8. G

    Valliant EcoTec Plus 831 always On!!

    Go into d codes see what flow is registering also s code will tell what boiler is doing if no leak on system could be plate h/exch passing into system, check prv for leak.
  9. G

    Wickes £49.99 WC

    Fitted one last week fantastic, cistern already fitted took 30 mins to connect no problems since fitted quality good reccommend them.Basically idiot proof
  10. G

    vaillant 828e boiler shutdown

    I had similar on a glow-worm energy saver combi traced mine to a dripping tap preventing heating coming on or for short cycle.Basically pre heat kept over-riding central heating,To prove turn dhw off on boiler or rising main and see if heating comes on then.
  11. G

    Gloworm Boiler F6 Fault Code

    F6 central heating flow ntc fault sounds like your plumber is telling porkies
  12. G

    Vaillant VCW242E

    Could be a shower or mixer tap letting bye if you have any ?
  13. G

    glow worm micron 50ff

    If it has orange led then give the boiler a thump it usually springs into life then change pcb when convenient.
  14. G

    Vaillant ecotek 824 - leaks from water sensor

    Had a flow sensor fail under warrenty Vailant fitted new sensor within 24 hours sprung a leak.Another vailamt engineer apologised and said clip was wrong orientation and had moved under mains pressure no problem since fitting clip correctly.
  15. G

    Jaguar boiler J1 error

    J1 is just telling you the boiler model.
  16. G

    Vaillant ecoTEC plus 418 - Does NOT Work - HELP!!!!!

    F23 could also denote flow and return pipes wrongly piped up.The combustion cover is on the heat exchanger so contrary to corgi is not illegal to remove cover.
  17. G

    lpg working pressure

    Quick question has the tolerances for lpg w/p on propane changed i work to 37mb +/- 5mb . Have been told some regulators now +8/-12mb if upso not fitted.
  18. G

    Glow Worm CXI 30 DHW problem

    Blocked plate heatexchanger F9 on your age boiler is a generic code.
  19. G

    GLOW WORM 30 ADVICE PLEASE

    Gasguru has told you the problem ,i had one leaking down the condensate.
  20. G

    Glow Worm Compact 100e

    The diaphrams are easy to source P/No S801191 .
Back