    Unswitched sockets

    Hi I'm looking at sorting out an area in our hall where we intend to have a modem and a separate router that already has a twin electrical socket (switched). Is it within regs to swap a switched socket for a non switched socket and / or add a non switched socket? Part of the works I'm...
  2. J

    Flex used in walls?

    Hi It measures 10mm across the diameter including the white outer sheath. Kind regards Justin
  3. J

    Flex used in walls?

    Hi Unfortunately I don't have those tools but have counted the stands to be 47 or thereabouts, might have missed 1 or 2. Kind regards Justin
  4. J

    Flex used in walls?

    Well I've measured across the diameter of the copper stranded core having made a fresh cut off the end and it measures 2mm so I'm confused now what type of flex this is. Kind regards Justin
  5. J

    Flex used in walls?

    Oh, when you refer to a size like that are you referring to the diameter of just the copper core? Kind regards Justin
  6. J

    Flex used in walls?

    Sorry, image sizes corrected. Kind regards Justin
  7. J

    Silicone bead against mosaic

    Hi Just wondering if anyone here has some pro tip on silicone sealing around a tiled area. I'm trying to get an en-suite shower cubical correct but it is tiled with mosaic. Using a silicone profiling tool, is there a way to get a level finish as the tool wants to drop down into each grout...
  8. J

    Flex used in walls?

    Hi I've not been able to return to this issue for the moment as it was something I was trying to get done on a day when I was without a power tool to get another area of the house done. Having had a glimpse through some more reply's since I last checked the thread I can clear up a few...
  9. J

    Flex used in walls?

    Thanks for everyone's input, I shall have to digest what this means for us tomorrow when we consider our options. Kind regards Justin
  10. J

    Flex used in walls?

    Would a photo of it be enough for you to be able to tell if it is 2.5mm? Each core measures about 3mm in diameter including its jacket. Kind regards Justin
  11. J

    Flex used in walls?

    If it turns out my neighbour has a fridge freezer on the same wall as my problem I may be able to get some coordinates of that socket, presumably somewhere behind one of three wall cabinets that I have.
  12. J

    Flex used in walls?

    I'm beginning to wonder if the previous owner added the cabinets at the end of the kitchen as I think my neighbour has an american fridge freezer at that end of their kitchen but shall have to call on them tomorrow to see which side it is on. Maybe there was once a socket higher up on the wall...
  13. J

    Flex used in walls?

    Something along the lines of the latter seems to be most likely. The only other sockets visible that are nearby is the one for the gas boiler and the cooker. The cooker is on its own circuit and I know when I switch the kitchen socket circuit off it turns off electricity to the sockets in the...
  14. J

    Flex used in walls?

    Certainly an alteration as I doubt the FCU and under counter socket were there originally. I believe the previous owner had a push in tumble dryer there and that they did this work for that as they also added the vent to the outside, none of which I believe is standard to the property's...
  15. J

    Flex used in walls?

    It certainly didn't look right to me hence it raised my interest as to what's going on. I'd like to make sure the supply and load are correct since a large microwave is used in the double socket as well as a kettle. The socket beneath the counter is intended for the integrated tumble dryer...
  16. J

    Flex used in walls?

    I'm not sure what you're asking me here? At the socket end of the Flex which is the only end I can access at present, Flex #1 is connected to the double socket as one would expect in terms of connections. There are separate cores from a piece of Flex that no longer has its' outer on...
  17. J

    Flex used in walls?

    It does have a metal divider, although I think this was just a plate at the front of the pattress box rather than a wall between both sides of the pattress box. Kind regards Justin
  18. J

    Flex used in walls?

    Definitely no conduit unless it's further up inside the wall. However, from my experience of the rest of the house, the original house builder didn't put T&E through conduit, its clipped to block work on the outer walls and rather unhelpfully dot and dabbed over in places. Kind regards Justin
  19. J

    Flex used in walls?

    I've currently no idea where Flex #1 and Flex #2 come from, other than they feed into the top of the pattress box. They appear to be on the Kitchen circuit due to no power on these when switched off at the CU. My markings for Load and Supply relate to the rear of the FCU. I've removed...
  20. J

    Flex used in walls?

    Interesting response. From that I take it you wouldn't approve of this, which was my instinct to it too. It might surprise you more to learn that I was informed the previous owner is an electrician, certainly his name or business name is on the Part P certificate we received for the electrical...