Search results

  1. M

    Kitchen / Extension

    depending on the size of the extension you may be able to do it under your personal development rights (PDR), in which case you will not need any drawings. you can do some yourself if you like, i used excel of all things. you will however need a structual/architect to work out the loadings as a...
  2. M

    Earth Wire

    im not sure if you understood my post. normally you would run a 10mm earth for the water and then another 10mm earth for gas. however it is acceptable to run a single 16mm to the water and then the gas(or viceversa) as long as the cable is continuous, ie not cut/broken anywhere including the...
  3. M

    wiring a cooker

    well why dont you help him out and advice him on how to connect it properly/safely, and share this secretive other way you was thinking about :lol: matt
  4. M

    New socket in loft.

  5. M

    introducing an shed earth rod and part p

    sorry for not making myself clear in the first instance, none the less a good discussion for people to learn from :) matt
  6. M

    introducing an shed earth rod and part p

    im not sure what you mean m8 :) you do not need the 3rd core, it gets disconnected at both ends. the armoured is protected by the armour sheath which should be earthed at the house cu but isolated from the shed cu. basically you are feeding the shed as an tt arrangement. why is every opne...
  7. M

    introducing an shed earth rod and part p

    if its been glanded and terminated properly it should. im sure i learnt this in 2391, i will try and find the info. matt
  8. M

    introducing an shed earth rod and part p

    sorry i meant to say "disconnect earth from house cu end aswell" matt
  9. M

    Earth Wire

    hi just another option you can bond the water and gas in 1 length of 16mm cable, as long as the cable is not cut at any point. hth matt
  10. M

    New socket in loft.

    hi m8 this is safe to do but not ideal. you need 2.5mmmm 3 core flex. hth matt
  11. M

    introducing an shed earth rod and part p

    hi m8 as far as i can remember the earth on a pme system should not leave the building. you need to put an earth spike in for the shed and just supply live and neutral, so 2 core swa would be fine. use 16mm from shed cu to earth spike. disconnect earth from house cu end. hth matt
  12. M

    RCD trips when switching lights off

    hi it does sound like a possible neutral problem, this sometimes happens if an protected neutral is in the unprotected side, but if its intermittent id rule this out. the appliances that trip the rcd, try them in the garage to see if they do it there. does the garage have its own earth, ie...
  13. M

    alarm wiring

    breezer, youre obviously full of usefull information, why do i have to work so hard to drag it out of you :D anyway thanks for the info just what i needed. i will do as Lectrician says and wire 1 detector per cable to be safe cheers matt +++++++++++++++++++++++++++++ i had...
  14. M

    alarm wiring

    because under the floor and in conduit flush mounted is a much more proffesional/tidy installation. im rewiring/plumbing the house so floors coming up and everything else is flush. if youve got to take the carpet up anyway they may as well be under the floor then, no? in conduit where the...
  15. M

    Wiring urgent help please

    hi m8 sounds to me like its wired in singles and the feed is at the switch. connect the red to live and the blacks to neutral, the green and yellow is earth. hth matt
  16. M

    alarm wiring

    No internal doors are to be alarmed. everything is chased, there are no visible wires. if i have no contacts i cant have any protection through the night, or am i missing something? i have quotes from installers but they are far too expensive compared to what i can put it in for, being an...
  17. M

    Single survey scheme - nail in coffin for DIY ?

    hi guys this is a fantastic idea. we are in the process of buying a property and our homebuyers survey has picked up on a few things which we were not aware of. if we pull out now we'll lose about £1000 of which about £600 was spent on surveys. so people will have to get there house in...
  18. M

    alarm wiring

    thanks for the info andrew so i guess that each room will have 2 zones. 1 zone for contacts and 1 zone for ir sensors so they can be isolated. its becoming a little clearer now :) do you know of any alarm related websites cheers matt
  19. M

    alarm wiring

    hi guys im moving into a new house and want to hard wire an alarm, but im unsure of what i can and cant have and need a little advice please. what i want to be able to do is:- 1)be able to disable ir sensors and just have door/window sensors on. 2)be able to isolate certain rooms ir...
  20. M

    This should be EASY - HELP

    hi bimmer did the light switch turn on ceiling rose and wall light? if so, was one of the swithes for the ceiling rose and the other for the wall light? have you taken switch of wall yet? without more information id say the B1 and Y1 at the ceiling rose are your 2 switch lines. connect...