  1. M

    Pressure loss

    I checked the auto air vent no leaks but I did notice the cap on the top was screwed shut Conflicting info online weather it should be tight or not
  2. M

    Pressure loss

    Thanks for the reply I have gone round all connections and can’t find any leaks I always get air in one radiator upstairs which is normal all others are fine It makes no difference how often I top it up I get this rush of air which I’ve never had before
  3. M

    Pressure loss

    I have checked the pressure relief pipe too and no leaks from there
  4. M

    Pressure loss

    I have a Worcester Bosch 28i junior boiler Last month or 2 I’ve had to top it up a tad every few days nothing drastic Have checked all connectors on radiators and boiler where I can get to Expansion vessel has been checked and is holding pressure fine I have noticed if the boiler is off and...
  5. M

    Blocking up chimney

    Hi all I brought a 1930s house and the chimney opening had been blocked up I drilled some holes in and fitted an air brick a few years ago the house has a tiny cavity but no insulation with how the bricks are built you can’t fit any in Fast forward a few years and the chimney stack is in a poor...
  6. M

    Bath side

    Hi all brought a new bath side last year I ripped up the old flooring which was tiles. Now I have reboarded the floor and put Lino type flooring down Trouble is the bath panel is too short I have made a bit of wood and used sealant on the edges Trouble is the bath panel design is slightly...
  7. M

    Garage roof advice

    Thanks any link to what I'm looking for
  8. M

    Garage roof advice

    Hi woody Thanks for the advice. Looks like another reroof inspected the wood today and some areas are past it I would say Serves me right for not spending enough time in there to notice lol
  9. M

    Garage roof advice

    Hi woody when it's warmer and it rains the wood shows no signs of leaking at all every morning in winter the underneath of the wood was wet
  10. M

    Garage roof advice

    Hi all moved into a house a few years ago with asbestos roofing that was tires broken leaking The garage has timber on the sides which has a slight gradient which I kept Ripped it up and fitted plywood and new felt all ok except a few areas pooling water Now this winter had caused some issues...
  11. M

    Generator running

    I tried it without the extra earth and still didn't work Putting a cable from neutral to earth has fixed it
  12. M

    Generator running

    Hi all yes it's a small generator. Looked online where some one said you have to run a cable to the neutral to earth ie it's a floating supply Have to admit the boiler fired straight away and has been running for hours happily. The electric board still haven't fixed the issues they have been...
  13. M

    Generator running

    Hi all been without power for awhile brought a generator a while back for this type of thing In the reviews everyone said they can run there combo boiler off them Got it running fitted the metal spike as earth as the instructions says.the boiler works but the burner tries to go but doesn't...
  14. M

    Wireless thermostat

    Hi all I have a Worcester digistat. I was having problems last year but I had a few bits of work done bigger radiator Problem is the stat isn't very accurate I leave it on 18 degrees over night which is fine and works well if I turn it above 20 degrees it doesn't seem accurate at all and the...
  15. M

    loft condensation

    probably a very common issue this time of year went in the loft for something. noticed the felt was quite wet. the type of house i have is a 1930s house originally with slate tiles but seems to have been changed for normal at some point (a long while ago) the felt is like a plastic so...
  16. M

    Corgi programmable unit

    Thank you any ideas where the grey from the diverter goes then I'm tempted to change the room stat as I don't think it's wired correctly anyway it's about 30 years old have a new Drayton one here I can test
  17. M

    Corgi programmable unit

    can you quote where its different?
  18. M

    Corgi programmable unit

    It does work just not the programmer for setting timings hot water works when you put it on if you move the room stat central heating works This is the layout if it. Makes sense exactly as the corgi website says
  19. M

    Corgi programmable unit

    The old controller was ancient. I have followed the corgi website to check for wiring and alls coreect I have noticed no2 hot water off doesn't have anything connected to it. It's / like the programmer doesn't cut the switch to the boiler http://corgicontrols.co.uk/?ddownload=687 Here's...
  20. M

    Corgi programmable unit

    My grandad has the above controller. Heating works if you turn the room stat and the hot water works if you press hot water on the programmer Problem is even if I set a heating timer whatever we do if we then the room stay up the boiler fires. I'm hoping to get it so the room stats on but only...
Back