  1. B

    Bentone Sterling 40 Oilfired Burner Cutting Out

    Burner cuts out. When I try to Reset, The burner fires for a short time. I have to reset six or seven times before fires. The Burner then runs for perhaps half an hour - presumeably until the correct watyer temperature is reqched. Then, I have to go through the whole process again and the...
  2. B

    Central Heater Burner Cutting Oyt

    Burner cuts out. When I try to Reset, The burner fires for a short time. I have to reset six or seven times before fires. The Burner then runs for perhaps half an hour - presumeably until the correct watyer temperature is reqched. Then, I have to go through the whole process again and the...
  3. B

    how to fit MCB onto Busbar

    Good Afternoon I have a 20 Amp Garo MCB How can I physically affix the MCB on to the Busbar? Has anyone got a leaflet showing info on the MCB Many thanks
  4. B

    Problems with porcelain polished tiles - tiles lifting and cracking

    Good afternoon, About 10 years ago, we had a new kitchen installed. My daughter had at this time purchased a new house and she had porcelain polished tiles installed in her kitchen on a cement floor. My wife wanted these tiles, and a coalition of other family members agreed. I was not too keen...
  5. B

    Immersion Heating Problem

    The switch is a Bath?Sink changeover switch - only one element is on at any one time. . Is it possible that there could be a short within the main element? Thanks Jimmy
  6. B

    Immersion Heating Problem

    I'm in the process of replacing my old fuse board with a Consumer Unit. It is in the planning stage Recently, I found that the 20 amp fuse feeding the immersion heater was blown. I replaced the fuse with a new 20 amp. After a few days, this fuse also blew. When I removed the fuse, the body...
  7. B

    What size step ladder should I buy?

    Good Evening all I want to do some drilling at a height of approximately 2 metres. What size ladder should I buy. How far apart would the legs be at ground level? Many thanks Jimmy
  8. B

    What size step ladder should I buy?

    Hi I need to do some drilling at a height of over 2 metres. I want to buy a suitable step ladder for the job. Could anyone suggest a suitablr size. What would the the leg spread be at tha bottom. ANny suggestions would be appreciated
  9. B

    Gate Valve on domestic central heating tank

    OK lads, I plead guilty - the 100mm entry should ofr course be 10mm . I'm having trouble sourcing 3/8 inch pipe - will a 10mm pipe fit into a 3/8 inch gate valve? If not will I need some converter to mate a 10mm pipt to a short piece of 3/8 inch pipe? Sorry for the confusion1 Jinny
  10. B

    Gate Valve on domestic central heating tank

    Good afternoon. The gate valve on my oil tand is rather old. It accepts a 3?8 inch copper pipe. Will I have any problems connecting a 100mm copper pipe to the valve? If the pipe will not fit, how can I get around the problem? Any help would be gratefully received! Jimmy
  11. B

    Bentone Burner Fireup Problem

    Hello John, Glad to be able to tell you that I replaced the Control Box and this cured the problem. Many thanks for your help. Later, out of curiosity, I used a junior hacksaw to extract the electrics from the defective control box. I found that the relay was mechanically goosed. - (to use an...
  12. B

    Bentone Burner Fireup Problem

    Thank you John. I'm 100 percent sure that electrodes are positioned correctly. The next problem is where to source a control box. The Control Box is a LOA24 173A27. I see that Siemens produced this control box, although it has Bentone stamped on it. A Siemens Control Box LOA24 171B2E is...
  13. B

    Bentone Burner Fireup Problem

    Hello John Following your suggestions, I checked the Photocell Resistance with no light = 120K Resistance with Led Torch shining into face = 1K I powered up the unit with the photocell covered and there was still no spark. Bearing in mind, that I have already replaced the ignition unit...
  14. B

    Bentone Burner Fireup Problem

    Many thanks John for your help and explanation of the boot up sequence Getting back to my problem, I replaced the ignition unit but the problem still persisted. I removed the burner from the boiler and powered it up on the bench. There was no spark visible. It seems to me that the problem lies...
  15. B

    Bentone Burner Fireup Problem

    I'm slightly confused. I accept your opinion that I have probably cooked the transformer. To check for a spark, can I simply remove the burner from the boiler by removing power and disconnecting the oil feed. Then, could I simply power the burner on a bench and press the start button and check...
  16. B

    Bentone Burner Fireup Problem

    Thanks John, Will check later
  17. B

    Bentone Burner Fireup Problem

    I have a Bentone Burner Sterling 128 app. 13 years old. Recently. the burner has been very difficult to start in the morning ofter requiring 4 or 5 resets. I noticed that there was a leak in the oil feed to the burner. I replaced the oil filter, the fire valve and re-tightened the pipe...
  18. B

    Bentone Burner - Oil Pump Replacement

    Many thanks Bob - Up and running - I am very grateful to you. Jimmy
  19. B

    Bentone Burner - Oil Pump Replacement

    I wished to replace the Oil Pump in my Bentone Sterling ST108 Burner. I studied a video produced by Danfoss outlining the steps to be taken in replacing their BFP 21 L3 Oil Pump. No problems except the video featured a different burner. I'm going insane in trying to figure how I can detach...
Back