    New Alarm Box Please help What wire to cut

    If I have no wires cut the alarm bell keeps going off and on the keypad it displays alarm bell Box tamper.. Please help
  2. K

    New Alarm Box Please help What wire to cut

    HI, I have a Eurosec control panel and I am wiring up a new alarm box. The alarm box has Cut White wire for Tamper Cascade options. EOL Resistance Cut All Except Black link or Brown for 1K Green for 4K7. Do I need to cut any wires...
  3. K

    CPX GardTec Eurosec Second Keypad 3 core wiring

    these power cable are not connected to anything so its not dangerous. However you guys have given me new hope. I do have a sensor near the first floor landing and has 4 cables free so do just split the out going from the main alarm box? 12v goes to both keypads 0v goes to both keypads D1 goes...
  4. K

    CPX GardTec Eurosec Second Keypad 3 core wiring

    these cables are just spare cables, they are not alarm cables they are spare power cables. Point A is just where the cables meet.
  5. K

    CPX GardTec Eurosec Second Keypad 3 core wiring

    ok so I have a keypad on the ground floor. There is a 8 core cable (I Think however only 4 in use) from the Keypad ground floor to the alarm main box. Then from the alarm main box I have a 3 core cable going from the alarm main box to point A. Then from point A I have a 3 core cable going to...
  6. K

    CPX GardTec Eurosec Second Keypad 3 core wiring

    Its a long story but I only have 3 cores from alarm main box to point A and then from point A to point B (Point B is the first floor landing) I have 4 cores. So in location point A I can add a 12 volt supply and a back up battery if required. Can anyone provide links of what I need for the power...
  7. K

    CPX GardTec Eurosec Second Keypad 3 core wiring

    Hi, I currently have a cpx gardtec alarm which works perfectly. The only thing is that my keypad is downstairs and I would like another upstairs. I have a cable from the alarm pcb to the upstairs hallway but is only has 3 cores, I know I need 4. Is there a way to get the this working. Even if I...
  8. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    Guys I did get a gas safe engineer to replace the blown board and check the boiler was all working fine. I wasnt comfortable doing it myself. However wiring nest is not hard if you are good with wiring. I still dont have a answer for wiring the second zone up Got another question. I have...
  9. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    Finally got it working last night. I was unlucky the first time as I did do everything perfectly however the pcb just failed. This one nearly beat me as I was very close to not trying it as I had bad fortune the first time. You right Agile, the whole idea to have 2 boilers was if 1 went down...
  10. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    If anyone can help with the pcb I would be greatful, i know it has 2 spare fuses which come with the boiler but theres only 1 fuse on thr pcb right, or is there a hidden one somewhere.
  11. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    Its not that big.. So do you think the pcb can be sorted or does it have to be replaced? Also cant understand why my first floor programer has a hot water wire to it. The second boiler doesnt do hot water, if I pressed the hot water button the light would come on but nothing would happen..
  12. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    I have 2 big dials for heating and hot water.
  13. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    Tried to change the fuse but no good. May try again tonight and pray it wont fail the second board.
  14. K

    Help Installing Nest Gen 3 with Vailant eco tech plus 637

    Hi Guys, I am a little cheesed off as I have already done in 1 boiler PCB board which I will have to order in. My Set up for the ground floor is: 1x Vailant 637 boiler which does my ground floor heating and hot water 1x Honey well programmer 1x Honey well Room stat. and my system is Zoned...