Search results

  1. M

    Dog leg connector

    Thanks for your help. I wanted correct alignment to the tiles nice and parallel. The solution for me in the end was to screw in the left dog leg at one turn less than the right to square up, keeping the same orientation to achieve 150mm centers. Previous attempts at thread sealing failed but was...
  2. M

    Dog leg connector

    Thanks for your help can you give me a link where to buy? Thanks
  3. M

    Dog leg connector

    Hi all.installing wall taps. Comes with cranked dog leg connectors. I don't need them have 2 individual 1/2 in wall plate elbow already at 150 mm spacing. So I want 1/2 inch male BSP to 3/4 inch BSP male but straight no crank. This will allow ajustment so taps are square to tiling. Does a brass...
  4. M

    Pyronix Enforcer HUD panic button

    Hi. Thinking of adding the HUD/MED panic button for the pyronix Enforcer V10 in upstairs on the landing so all my family has a way to activate alarm if they suspect unwanted visitors around our car/ property. Has anyone installed one and is it easy to program?
  5. M

    Mother's Day helium balloon

    Thanks. Now left under the table. Wifey will be puzzled.
  6. M

    Mother's Day helium balloon

    Daft question but a helium balloon slowly spinning in the room near a pir sensor will this cause an alarm due to movement.I can't remember if it's heat or movement these sensors detect. Ta.
  7. M

    Pyronix dome cameras and home control app

    Hi guys. Thinking of getting a pyronix dome camera. I have the Home control app will work with this app? Or do I need the Pro version? Cheers.
  8. M

    Pyronix enforcer tamper on input

    I will take your advice I will take it down either replace the microswitch or get a replacement Deltabell E. What would you do?
  9. M

    Pyronix enforcer tamper on input

    No zone 33 in panel set to tamper
  10. M

    Pyronix enforcer tamper on input

    Thank you for replying. I checked yesterday that the adjustment screw on the bell box was adjusted so to push the rear of the switch closed. Front cover snug. Strange how it's decided to fault after two months. Cable is fine checked for breaks in the loft. As mentioned the wiring in panel has no...
  11. M

    Pyronix enforcer tamper on input

    Hi. I have had the system running for a few months. It's hard wired to a deltabell E. Input at panel is set to tamper and the bell has the 2k2 resistor wire from 0v to T. It's been fine all this time I've checked the siren lid and Microswitch rear screw their ok. So now I've disabled input 33...
  12. M

    How to test a hard wired pyronix deltabell E from pyronix enforcer

    Thank you all for the help. It was indeed the output settings changed them as suggested now working fine. Many thanks again.
  13. M

    How to test a hard wired pyronix deltabell E from pyronix enforcer

    Ok will check in the morning looks like I need to do this while the siren sounding
  14. M

    How to test a hard wired pyronix deltabell E from pyronix enforcer

    Now when I enter engineer code the hard wired Deltabell siren sounds any idea why
  15. M

    How to test a hard wired pyronix deltabell E from pyronix enforcer

    No wires connected to hold off I've been adding another pir this morning which is working fine so the clue is I've somehow altered the program when I was trying to test the hard wired siren
  16. M

    How to test a hard wired pyronix deltabell E from pyronix enforcer

    Yes it worked when first installed But now have a problem with the wired siren it goes off when I go into engineerins mode
  17. M

    How to test a hard wired pyronix deltabell E from pyronix enforcer

    Hi I have the wireless bell connected which works under test mode. The hardwired siren only the strobe activates with no sound. Any ideas why it doesn't sound? Thanks
  18. M

    Pyronics enforcer w.e to Deltabell wiring

    Well replaced the resistor for the correct 2k2 and all is working as it should bell tamper display on panel and panel sounding many thanks to all who helped me here we go up the ladder god I hate nights
  19. M

    Pyronics enforcer w.e to Deltabell wiring

    Well I've got a 4k7 resistor in the bell box thinks this will need to be a 2k2 and select this value in the "wiring choice" Would the wrong resistor give me the problem I am having?
  20. M

    Pyronics enforcer w.e to Deltabell wiring

    Yes I've have programmed input 33 to tamper but should I select no to areas ABCD when prompted
Back