  1. B

    British Gas fire

    Cheers. Spot on
  2. B

    British Gas fire

    I require a part for a ilfe fire. a gas valve. the only thing is, on the data badge it is named as a british gas contempary deluxe. G.C. 32 210 15. Now the system at parts center is showing up as there is no such fire so obviously british gas have stuck there own name on it. Does anyone have any...
  3. B

    Glowworm 30CXI

    the hot water control knob will be pointing to the red area ( mostly clocwise) you need to turn it below the red area to stop it pre-heating the water. the white area is min to max temp without pre-heat and the red area is min to max temp with pre-heat
  4. B

    Worcester 28si II

    There is only one heat exchanger on your boiler. It has no plate to plate but a twin pipe running through the single heat ex. Yes they do split inside and cause the mains water to mix with the ch water causing the boiler to continuosly pressurize but you may want to check the filling loop has...
  5. B

    bouncing pressure gauge needle

    Does anyone know if there is a return filter on a worcester 24i. I'm guessing there is but not 100%. The needle is bouncing about when the central heating is on and I'm hoping it is just a filter blocked and not a blockage in the heat ex.
  6. B

    Help Required - Combi Boiler

    possibly the pump not working so the flow switch is not making
  7. B

    Worcester-Bosch boiler problems

    that is exactly what i thought as i had one with the exact same symptons and the problem was the condensate waste was plumbed into the sink waste as was the waste from a dishwasher and the dishwasher waste had caused a blockage in the last elbow on the condensate pipe causing the combustion...
  8. B

    Ideal Classic boiler - where is the overheat reset button?

    isn't it an electronic ignition so it wont have a permanenmt pilot. the problem will be that your fan has stuck
  9. B

    Heating system stopped working Thorm Apollo Boiler

    what are you talking about 3 minutes? 10 seconds is long enough for a thermocouple to produce enough voltage to hold the electromagnet if there is an interrupter (overheat stat) then how can you tell thats not faulty?? how can you tell its not a faulty electromagnet in the gas valve?? if the...
  10. B

    Hot Water, boiler overrun ..

    have you altered pipework and capped some point off leaving air in a length of pipework somewhere ( a dead leg) you will need to bleed this air off as it could be causing movement of water through the boiler for a couple of seconds keeping the burner on before it stabilises
  11. B

    Hot water tap takes a long time to produce hot water

    i'm wondering whether a faulty thermostatic mixer valve could be the problem (if there is one on the system anywhere)
  12. B

    Fauly Thermostatic Radiator Valve

    yes you can just change the head and europa is probably just a more familiar model renamed. just take it to a plumb center and they will know what will fit
  13. B

    Fauly Thermostatic Radiator Valve

    a trv is suposed to be either on or off isn't it
  14. B

    worcestor 24i no flame

    check the wires themselves. what you are doing is checking the resistance of the gas valve solenoids which one will more than likely be an open circuit and the valve will need replacing
  15. B

    Chaffoteaux & Maury

    I'm pretty sure the red light is ignition failure. basically if there is a spark there, for some reason there is no gas getting through. check meter if quantum it has gas and hasnt locked out. make sure you haven't knocked the gas cock off under your boiler. if everything looks ok then there...
  16. B

    potterton lynx 2 combi

    there is no diverter on a lynx2 there is a flow switch on the right hand side right at the back with a grey (i think) wire coming off it and these often stick and need replacing and can be a bit of a nightmare to change. to check it just follow the wire from the flowswitch pull the connection...
  17. B

    Loud Noise from Combi-Boiler

    could be the solenoid on the gas valve
  18. B

    Help with Central Heating ...

    well it sounds to me as if your pump hasn't enough power to pump the water back upstairs from downstairs anymore therefore i would turn your pump to number three and see if that helps
  19. B

    C & M Brittony 80 making a whining noise.

    yeah try that first and i apologise in advance if i have wasted your time and it turns out to be the fan after all!