  1. C

    Macerator

    but still don't understand why bath won't drain away.
  2. C

    Macerator

    that's what I thought but don't fit these often, in fact normally won#t go near them. Cheers
  3. C

    Macerator

    cheers yes pipework is 22mm (0.5 metre) then into 32mm (7metres)gradual fall to vertical soil stack outside, soil is vented to open air above roofline. don t have pics and pipework is below tiled floor. If I hold bath plug down it pumps out into soil stack. thanks
  4. C

    Macerator

    hi thanks it vents to outside, it is a run under the floor of 32mm falling about 7 metres then outside into the soil stack, the soil stac is open air above the roofline. cheers
  5. C

    Macerator

    The bath has a trapand is into the left hand side of the macerator as per instruction, toilet is as usual, when we flush the toilet it just pumps it into the bath so confused. its a sani pro xp, he macerator pipework is 22mm then 32mm no tees etc all the way to the soil stack. cheers
  6. C

    Macerator

    Hi We have just fitted a macerator, (only fitted one before a few years back), we have run the pipework as per MIs. But when we flush the toilet it pumps it into the bath which is connected to the other outlet. The bath doesn't drain either. Am I being stupid as as far as I see it chews up...
  7. C

    Macerator Tee

    Hi Cheers that was my gut feeling, two pipes it is. :roll:
  8. C

    Macerator Tee

    Hi Just been asked to move a bathroom, we will not be able to get a fall on a 100mm soil pipe so the only way is to fit a macerator. The problem being the bathroom will only be wide enough to fit a WC and bath side by side and the basin at the other end of the bathroom. |Having only ever...
  9. C

    MR16 LV LED Light on a Dimmer

    Susses it, either a v pro dimmer or a 10 watt bulb, internet love it, or a resistive load, bad day today lol
  10. C

    MR16 LV LED Light on a Dimmer

    Hi A customer has just asked if they can have their one MR16 LED light on a dimmer, no problem says me, then thinks about it in the van on the way home, there is a minimum wattage on low voltage/trailing edge dimmers, they only have one light, on my nose around I found this to be 10W, now...
  11. C

    Dimmable Lights

    Thanks meant a low wattage dimmer, just need to check the lamps really then for what driver to use. cheers
  12. C

    Dimmable Lights

    Hi Got a customer who has asked me to replace some light bulbs for LED ones, they are on a dimmer, the lights are 4 x GU10 50watt and 1 x MR16 Low Voltage (in a fan light). The way I see it I need to remove the fan from the set up on its own pullcord and power. Change the dimmer switch to a...
  13. C

    Constructionline

    Hi Guys Thanks for the replies, got the tender through and after looking at 220 pages of 475 thought better of it, couldn'tt beleive what they were asking for, and no guarantee of the work, stick with what we are doing :)
  14. C

    Veritas R8 Fault

    Hi Thanks for the reply, no keypads beeping and everything so seems to be working in that sense. Thanks Ian
  15. C

    Veritas R8 Fault

    Hi everyone Fitted a veritas R8 twos months ago, customer just called me back to say that the system won't full set only part set, nipped round for a quick scan, couldn't get it to full set either, so tried my engineer code to enter programming, wouldn't accept that either, so re set the...
  16. C

    Advice on how to quote for a chimney breast removal

    Hi SE costs seem a bit steep but BC is about right, we pay about £250 - £300 for the calcs normally on a job like that but suppose depends where you are. 8)
  17. C

    Constructionline

    Hi we are in the process of tendering for a job, the customer has said they would prefer if we were registered with Constructionline. Whats the pros and cons with registering with them. Anyone a member. cheers Ian
  18. C

    Horstmann CentaurStat 7 Installation

    Hi Thanks for the reply, will try that, not sure if we have already tried it but will give it a go again, and let you know. cheers for the reply. Ian
  19. C

    Horstmann CentaurStat 7 Installation

    We have fitted the above programmable roomstat to an existing system, we removed the old style stats. The problem lies in the fact the stats come on at the time and or temperature required but they don't switch off when they have reached the required temperature. On the Wiring diagram it has 4...
  20. C

    Thermostat Change

    Hi We have changed a manual thermostat to a programmable thermostat on a printing compnay, 4 in total, they operate a ceiling mounted gas burner, we swapped as they were, but they are not working probs, bit perturbed, the problem seems to lie with the temperture setting, it is 10 deg in the...