Search results

  1. G

    Listed building consent

    Hi all Im currently looking to buy a grade II listed building which currently has uPVC windows to floors 1 and 2. The propert consists of a ground floor shop with a 3 bed maisonette above. The shop front is an old wooden canopy with pillasters and wraps around the buildin which is on a corner...
  2. G

    Whirlpool AWOE 9558 drum problem

    hi again just a quick update, I phoned Whirlpool again to tell them that I thought it was unfair to have to pay over £200 for the part when the machine is only just over its 12 months guarentee and the man I spoke to told me that the bearings on my model have a 2 year guarentee!! They are not...
  3. G

    Whirlpool AWOE 9558 drum problem

    had a feeling you might say that! Might have a look for a new machine instead. Thanks for your help
  4. G

    Whirlpool AWOE 9558 drum problem

    hiya thanks for your reply. The service number on the door is 8592 979 15000
  5. G

    Whirlpool AWOE 9558 drum problem

    I am having prolems with the above washing machine the drum is really noisy so I took the belf of and spun it manually and the drum still made a noise I thought it may be the bearing or the "spider" anyway tried to remove the bearing from the back and i cant so looked to remove drum and found...
  6. G

    Makita hammer drill

    Thanks guys its in bits as we speak, it does rotate fine I think its the ameture as well but don't know how to check??
  7. G

    Makita hammer drill

    Hi I have a makita HR3000C sds rotary hammer drill that yesterday while core drilling stopped working. It just wont turn when you press the trigger, it makes a buzzing noise and tries to turn but then starts smoking and blows the RCD. I don't know if it could be the armiture or something...
  8. G

    Wet dashing dormer cheeks

    Hi I need to wet dash (to tie in with the rest of my house) some dormer cheeks they are currently lined with 18mm ply and a layer of tyvek. I have looked at eml and bluclad board but am unsure which is best to avoid cracking I also live facing the Irish Sea so get alot of weather. Any help...
  9. G

    Powerflush

    In my opinion he can't sign off your work unless he himself is corgi registered, you don't 100% need a powerflush but it would be better but would add cost and as its not a combi a chemical addative flush should be ok. Also you do need thermostatic valves.
  10. G

    Vaillant 837 / 937

    To answer your first question though, yes you can turn off the preheat.
  11. G

    BAXI BAHAMA

    there is low fan speed because 1) i've seen it and 2) baxi themselves said it would go to low fan speed?? I have no instructions the guy from baxi told me pin 8 and 10 control the demand With all this in mind do you have any idea????
  12. G

    BAXI BAHAMA

    even though the fan drops out at the same time baxipot???? why would the gas valve drop the fan to low speed??
  13. G

    BAXI BAHAMA

    external switched live has been bridged, signal from dv is constant, ch sensor is dry clickson stat so had one on van and tryed, I don't know how it checks system pressure I don't think it does prob relies on overheat???? Im thinking wiring loom etc but yes thanks chris it is a good one and...
  14. G

    BAXI BAHAMA

    There is no contradiction baxipot the dhw works fine, lights first time everything. The flames and the neon light. I don't know how well you know these boilers but I do know them quite well as I have repaired many over the years and I know the flame lit neon comes on as the burner comes on...
  15. G

    BAXI BAHAMA

    no orig installer didnt fit return filter I have checked that aswell. Chrisr the aps stays on until after the fan cuts out so thats working ok. If you think about it there is something turning both the gas valve and the fan off at the same time, on the gas valve controller pin 8 and pin 10...
  16. G

    BAXI BAHAMA

    Think I shoud point out here that I am a heating engineer so am familer with correct polarity etc. but this has got me so confused that I wondered if anyone else had any thoughts i have fixed loads of these in the past so am not a complete novice.
  17. G

    BAXI BAHAMA

    yes both those chrisr but its not getting to that stage of flame retifacation
  18. G

    BAXI BAHAMA

    no its not even getting to flame sensing stage flame retifacation usually takes about 8 seconds but this is dropping out in less than. Its not aps or electrode because hot water is fine. Its honeywell I meant the controller box but I call it cantoller board. It can't be the gas valve as fan...
  19. G

    BAXI BAHAMA

    cheers gazza checked all those things already this is a real b*****d
  20. G

    BAXI BAHAMA

    Hi guys I need some help on a baxi bahama, on central heating it lights for one second then goes out immediatlly then relights again it does this several times each time only lighting for one seconed. After about six times it either lights or goes to lockout. The boiler lights first time...
Back