Search results

  1. F

    landis and gyr prepayment meter

    can anyone tell me if it is possible to gas rate an appliance with this particular meter. if the A button is pressed to select the display to units consumed in cubic meters the reading will not update in real time,making it impossible to do a rating.
  2. F

    Combi boiler flue linking to gas fire flue

    as a landlord i would advise that the gas fire is removed.one less headache for you and your tenants..
  3. F

    Ariston microGenus 27MFFI no hot water Intermitent fault

    i think that the minimum burner pressure setting on the gas valve needs resetting.common fault on these boilers. as we all know do not attempt to do this yourself.
  4. F

    Baxi 105E Instant

    check pump is turning for circulation.is there an air lock in the heat exchanger. does the flame modulate before overheat if not dhw sensor at fault check the resistance
  5. F

    ideal isar fault

    yes it was the wiring and thermistor not pcb. problem is thermistor does two functions water flow and temp reg. agile why register for the chamber when most of the replies are off topic and of no use.
  6. F

    IDEAL ISAR Condensing Boiler problem

    the heat exchanger can be removed and cleaned.the main problem is removing the sludge from the pipework and radiators which will clog the heat exchanger up again. you would have to powerflush the system not cheap.
  7. F

    ideal isar fault

    no i will not charge for the board,and i will continue to find the fault with or without you negative attitude.r
  8. F

    ideal isar fault

    so whats your problem
  9. F

    ideal isar fault

    thanks for the help. I i did not relpace the spring valve just cleaned and greased it so it was running freely.the water was clear and no sign of sludge. The fault seems to appear if it has been left standing for some time. could be the valve is sticking intermittently or the actuator is.
  10. F

    ideal isar fault

    I have a problem with an Ideal Isar 24 He.The problem initially was no central heating with fault codes H3 and L E. I found the diverter valve was stuck removed it cleaned up and refitted fired the boiler and went through the D and C sequences all was working fine. I got a call back that the...
  11. F

    stop the warmfront farce

    There is a petition at No.10.It seems with just 26 signatures a little help is needed. http://petitions.number10.gov.uk/GRANT-HEATING/
  12. F

    vaillant ecotec plus problem

    good boilers those vaillants
  13. F

    problem with a customer

    there must be three parts to a verbal contract in this case there is. 1 the offer 2 an agreement by the other party 3 a consideration (payment} this is very simplistic but fundamental to determine whether there is a contract or not
  14. F

    problem with a customer

    you have a contract with your customer even though it is not written a verbal contract is law.you have forefilled your part of the contact and the customer has breached the contract by not paying up. you should try to reestablish contact by calling in person and come to an arrangement,you have...
  15. F

    My Baxi Combi 105HE is whistling a lot!!

    do you recognize the tune
  16. F

    POLYORC PLASTIC PIPING

    try looking at the previous post. //www.diynot.com/forums/viewtopic.php?p=218054&highlight=#218054 the plastic pipe is now so old it is very brittle especially near the joints .i have managed to buy the joints as the piping is still used in the chemical industry.i it is better to...
  17. F

    Suprima 80

    check for reverse polarity
  18. F

    No pressure - Worcester Bosch combi boiler

    get the engineer to trap some air in one of the radiators this will act as a temporary expansion chamber .
  19. F

    How do you unblock a blocked micro bore system?

    if the system is not is non combi. you could reverse the pump with the boiler switched off ,to release the blockage before you start cutting pipes. builders will use the cheapest sub-contractor regardless of quality