  1. 2face

    a long shot... pool boiler manual

    this is a real shot in the dark here... i have a repair on a purex / tropic isle pool boiler and some fool has walked away with half the bits and manual .. so need a manual for the boiler so i can hopefully re instate the boiler for the summer .. hehe summer thats a laugh .. any way thanks...
  2. 2face

    raven heat 100e (not the condenser)

    i have a little problem with a ravenheat. it is not modulating there stays on low gas .. as this is the only one fitted in south yorkshire as they are the worse boilers in the world .. i am hopeing someone can shed a little light on were i should start .. i am guessing the gas valve...
  3. 2face

    does any one use the easycert software

    as topic says has anyone bought the easycert software and if so is it worth the expense cheers lads.
  4. 2face

    what are your views on this diy install ?

    hi, i have been approached by a local builder to connect gas to a new boiler he has fitted in a bungalow. i dont agree with this kind of work so declined the offer and said it was illegal for him to fit a boiler. what are your views of this and do any of you lads agree with this ?? cheers
  5. 2face

    ikon boiler manual

    i have looked high and low for this .. can anyone help .. i have a visit later in the week and would like to take some spec with me as a back up .. cheers lads .. either a link or an email would be great .. thx again . :)
  6. 2face

    part p tester wanted

    hey can any one help me i am after a megger or fluke mains/insulation tester .. the 1502/2 or fluke any of the 3 models or even the metrel easy test will do me .. :) thx in advance lads.
  7. 2face

    ferroli falcon help...

    before u say anything lads i know they are ****e .. i have gone to a repair today the 2 amp fuse is tripping in the pcb have checked everything and all seems ok replace the fuse and it pops striaght away .... as per usuall sticking switches on the board .. ! replaced the board and...
  8. 2face

    heating installer need some work contacts.

    i am a contract heating fitter and have been for the past 15 yrs . i have just split from my partner after 12 happy years .also in the area i live ie:sheffield there is a lack of refurbs in this area (generally council re-fits) any contact numbers would be appretiated (sub contract works)...
  9. 2face

    question for a mod .

    i was asked to edit my signatire ?? just wandered y that was .. ? ++++++++++ It looked like an advert Mod Rupert ++++++++++
  10. 2face

    gas hob tech question

    when fitting a hob i have always been under the understanding that the tolerances are 750 above the flame to the extractor and 150 to either side of the flame this is the area of no units .. now i am told it is 50 mm either side of the hob unit . does anyone have any links to aid me in this ...