Search results

  1. G

    extraction fan termination on pitch roof

    hi i have just discovered i have to fit an extraction unit in the ceiling of a bathroom above a shower, the ceiling is horizontal and has two layers of plasterboard fixed over an old lathe and plaster layer so is pretty thick. there is then about 18'' of space between ceiling and the...
  2. G

    new light fitting very dim

    thanks i have access to a multimeter but don't know what/how to test i know which cable supplies the second fitting which just leaves three how do i test for which is the switch drop, no loft available unfortunately!
  3. G

    new light fitting very dim

    hi this morning i had two light fittings working fine, controlled from a single dimmer switch. i have replaced one light fitting which involved moving the ceiling rose slightly, so the wiring to that rose was disconnected. i thought i was very careful to reconnect in exactly the same way...
  4. G

    commercial paperhanging

    hi not sure if this is the best site for this question but here goes i am a building maintenance contractor stepping slightly out of my comfort zone, i am quoting for a job, much of which is basic decoration of woodwork and ceilings, however a significant part of it is removing and replacing...
  5. G

    replace box sash windowsill !

    thankyou very much symptoms, good clear info, when you don't know exactly what happens in the bit that's not visible it's good to hear a word from experience, especially the sill size difference, that saves a lot of unnecessary legwork. it's appreciated !
  6. G

    replace box sash windowsill !

    hi i need to replace a window sill on a box sash style window as the existing one is rotten, i have two concerns really, firstly how to get the existing one out with as little damage to it's surroundings as possible, is the 'box section' which sits on top of the sill generally fixed to...
  7. G

    flat roof construction/ fixing timbers

    ok thanks for that
  8. G

    flat roof construction/ fixing timbers

    thankyou for that, thought i should be doing something, just wasn't sure it's appreciated
  9. G

    flat roof construction/ fixing timbers

    i am building a flat roof on top of existing single skin brick wall enclosure/garage style walls, with a span of 2.6m and 4m length, i have 6"x2" joists and firings cut to 1:50 gradient across the short span. my plan was to affix a 4"x2" wall plate on top of the brick wall and stand the...
  10. G

    refilling microbore radiator

    thanks for that, i'll check the ball valve, if that works ok and the outlet to the cold water feed from inside the tank is clear do you have any suggestions as to what the next step to finding a blockage would be ?
  11. G

    refilling microbore radiator

    I have recently decorated a friends room, and took down the radiator on a microbore system, the valve is a two in one type (ie. both in and out at same end of radiator) i closed both inlet and outlet, removed the radiator and reversed the process to reinstall it. to refill it i opened the inlet...
Back