  1. N

    Monoblock tap head removal

    Hi Its the lever I cannot remove. Any ideas. Cheers
  2. N

    Monoblock tap head removal

    Hi I have a constant trickle of water coming from single lever tap. I have taken out a small allen keyed nut but the head does not come off to allow me access. Can anyone advise what to do next please?
  3. N

    Vaillant turbomax 282

    Hi After servicing above boiler there is a delay on the heating side. Hot water fires up instantly. But when thermostat is turned on, the Heating light comes on at boiler, but there is a 3 to 5 min delay before boiler fires up for heating. If i turn boiler off then on again it fires up...
  4. N

    COMBI FOR LOFT CONVERSION

    Hi At present we have a terraced 3 bed 1 bathroom( thermostatic shower) house. We are thinking of having a loft conversion ( 1 bedroom and shower room. 2 rads) Would our existing Combi (32kw. 13.1 litres per min flow rate) be able to cover this extra load. Our showering at present is spread...
  5. N

    Baxi solo 3 pf Intermitant sparking

    Hi can anyone help. Sometimes it sparks and lights pilot. Other times I tap on cover and this sparks and lihts pilot. Any ideas what might cause this. Thanks.
  6. N

    ideal classic

    Thanks. water is coming out of rad not air. In airing cupboard there are two vetical pipes that seem to have a hand tightening type nut not sure which one to undo
  7. N

    ideal classic

    Hi Can anyone help. I have a Traditional S plan system 2 zone valves etc. I have just drained down heating side. I have 7 rads and fitted 6 trvs leaving one normal. The problem is that the boiler doesn't seem to stay fired up for long on heating only and one rad makes a gurgling noise ( been...
  8. N

    TRVs

    Hi not combi. In cupboard there is a pump just above is zone valve with only 1 pipe going in then 1 out the other side is this any help.
  9. N

    TRVs

    Hi Firstly: I would like to fit TRVs to my Rads the thing that is making me think twice is that The Lockshield valve is at the bottom of the rad, but at the other end where the TRV would go the pipe goes into the top of rad. Can I change it with a new trv to go in the bottom of rad or do I have...
  10. N

    Intermitant hot water from combi

    Hi Yes this is what happens Thanks
  11. N

    Intermitant hot water from combi

    Hi it works on central heating. Yes water gets hot then goes cold boiler does not shut down.
  12. N

    Intermitant hot water from combi

    Hi i am getting intermitant hot water from my vokera linea 24. Can anyone help.
  13. N

    Vokera linea 24

    Yes you were right it is a Vokera Thanks for that.
  14. N

    Vokera linea 24

    Hi. My vokera linea 24 keeps giving me intermitant hot water. It runs hot for a little while then goes cold. Any ideas please.
Back