Search results

  1. D

    honeywell g2 keyfob zones

    Hi i have a g2-44 honeywell panel and want to add keyfobs to system as i understand it, as standard the panel has 44 zones that can be wired or wireless question is when the keyfobs are registered on system which zones does it take up on the panel, and how could i check this. Think im right...
  2. D

    keypad location porch??

    Hi is there any reason why not to mount alarm keypad in front porch of house outside of entry/exit door Just thinking it would be better to arm/ disarm before entering protected zone via keypad/keyprox Thanks
  3. D

    max3 prox reader location

    Have got a a galaxy g2-44 and max3 prox reader can someone tell me if prox readers in general are ok to locate outside entrance of property before entering so arming and disarming done from outside.. Is this perfectly normal maybe recommended route? any reason not to do this? Thanks
  4. D

    isolation valves arrow

    normal iso valves (type you turn with screwdriver) why have they got flow arrow marked on them? looks physically the same whichever way around would it affect flow if wrong way around? thanks
  5. D

    13a fcu/ rcd feeding conservaory + lighting

    13a fcu / rcd feeding conservatry off ring feeds 2 x dbl sockets and two lighting points noticed there is no seperate fcu for lighting but fed off same 13arcd is there a requirement for seperate fcu or is this ok also on test results what is given for zs on the circuit is it 1667 because...
  6. D

    unvented cylinder what is this picture attached????

    what is this picture attached and what is it used for used for on unvented cylinder circuit?? picture attached //www.diynot.com/network/darren bergin/albums/ i want to fit a new radiator and need to drain heating sytem down any advice please thanks sure what ive got is on a s plan!!
  7. D

    sealing shower tray onto floorboards + tanking

    im about to fit a low profile stone resin quadrant tray direct onto floorboards.. flooorboard are solid no movement,,,, ive also brought some easybath tanking also couple questions whats best to bed shower tray down with ??? i fear sand cement mix would crack up over time how do i seal...
  8. D

    low profile shower tray onto floorboards & tanking

    im about to fit a low profile stone resin quadrant tray direct onto floorboards.. flooorboard are solid no movement,,,, ive also brought some easybath tanking also couple questions whats best to bed shower tray down with ??? i fear sand cement mix would crack up over time how do i seal...
  9. D

    split load board zs on cert

    what do you put for maximum zs value on a split load board ring circuit protected by 30ma rcd do you look at tables in regs book or is it just 1667 thanks
  10. D

    measured zs too high vs calculated

    sce4nario measured zs with meter too high! above max permissible zs but calculated value is well within specification what gives?? is the circuit ok? what do i do on test results?? thanks
  11. D

    CAPPING hate putting on this stuff (is it just me?)

    Hate putting metal capping on to cover cables . I know we have to do it ..but banging fingers! nails jumping out .. capping pops off grrrrrrrrrrrr any easier ways????
  12. D

    New shower tray & enclosure making watertight

    About to install low profile shower tray whats the best way to ensurethat this will be forever leak free? do i recess it into the wall slightly ? use some kind of sealant strip or plastic sheeting against wall or just sealant?? thanks
  13. D

    double oven and hob off same supply

    this is what i have electric cooker and hob 40a rcbo at consumer unit 6mm twin and earth feeding ccu (type with 13a socket on it) cable is about 5 metres long clipped direct to joists double oven says it rated at 20 amps hob 6kw oven and hob are both fed with individual 4mm cables...
  14. D

    double oven and hob opposite sides of room

    I have currently a cooker circuit fed by 40a breaker to cooker switch. Is it possible to wire my hob onto the outgoing of switch and run a 4mm cable off incoming side (daisy chained) over to other side of kitchen to feed another cooker switch that supplys double oven manufacturers spec...
  15. D

    flush recessed socket in single brick wall

    whats the best way of fitting a recessed socket into a single bricked wall without ruining other side of the wall when chasing out thanks
  16. D

    fitting stone resin shower tray

    Just about to fit a stone resin shower tray onto wooden t &g floorboards Can i place this tray direct onto floorboards held with mastic, or should i make a wooden frame & base for it to sit on? i hear tilng should be done afterwards for a more waterproof fixture any help appreciated before...
  17. D

    fitting new rad without draining down

    Is this possible i Have an unvented cylinder but central heating i think am right in saying is vented because i have a tank in loft i want to pull a plastic pipe (push fit ) off existing rad to change trv if i switch off the rad and drain will i be able to pull plastic feed pipe off and...
  18. D

    plastic piping inserts

    Never used plastic piping before SO on every joint must you use inserts On every compression and every push fit connecter??? im about to add another rad existing pipework is plastic 10mm thanks
  19. D

    is this possible??? variation to two way lighting circuit

    if two independent switches were feeding two independent lights respectively Could a master switch (2 way switch) switch off both of these lights? how could this work? thanks
  20. D

    flexible armoured cable outside

    can you use flexible armoured cable to feed outside lighting buried underground and ran surfsace mounting without any additional protection..? i know normal swa cable you can use just wondering if same applied to flexible armoured thanks
Back
Top