Search results

  1. K

    Ideal Isar problem

    Ideal Isar HE30 Hi all we have this boiler - im aware that this boiler ain’t the best but when I call for central heating the burner lights up for about 30/40 seconds then goes out - fan continues to run then after 2 minutes the burner kick in again but for about 40 seconds then goes out - is...
  2. K

    Noise from shower until hot water - Grohe Automatic 2000

    Hello I have the above shower and have a problem where there is a horrible noise in the pipes around the shower until hot water comes out of the shower head - then it stops The shower is powered through my central heating boiler (new Baxi combi) - before that i had a vokera with the same...
  3. K

    Hoover S220 Washing machine fault - NOW FIXED

    I have the above washing machine and have a problem Half way through a programme I switched it off a few times and now it will not work - it fills and drains OK but wont start. The brushes seem fine and the motor is 12 months old - any suggestions? Ken
  4. K

    Vokera Flowmatic 20/80 - any service engineers in brum

    Anyone in the midlands area that can give me a quote to service my Vokera Thanks Ken
  5. K

    banging pipes - Water hammer?

    When I turn the shower on or a hot tap I get a massive clanging noise and have had this for several months - I am now in a position to get this fixed and called a plumber for advice. He said its most probably water hammer and said that I will need 1 or two devices fitted in to the pipes to stop...
  6. K

    Vokera 20/80 Flowmatic hot water problem

    Hi, I do not know if there is a problem or the fact that the temperature outside might be causing the issue. My Boiler seems ok but the problem is that you have to have the shower on really fine to enable you to have a warm shower. When you run a bath you have to turn the tap to almost...
  7. K

    How do I get rid of air lock??

    Hi, Every time we turn the hot tap on in the house, there is a horrible noise (air lock) We do not have a tank in the loft - can somebody give us the procedure in getting rid of it!! Cheers Ken
  8. K

    No earth wire - safe outside??

    Hi all, I have a pond air pump and have noticed that the internal wiring has no earth connected - is this safe to use outside in a shed or should I return it Regards Ken
  9. K

    Vokera pin staying out on CH Manifold

    Boiler - Vokera 20/80RS Flowmatic Noticed the Pin staying out when not calling for Central Heating but when you call for Central heating it goes in and the heating comes on - is this normal!! Thought it was the other way round... Ken
  10. K

    Shed build - idiots guide

    Can anyone give me some pointers to building an eight foot square shed and six foot in height with a sloping roof - must include window and door!! Ken
  11. K

    Vokera 20/80 flowmatic 3 way diverter valve leaking

    Hello, I have the above boiler and there is a leak when you call for hot water between the 3 way diverter valve and domestic distribution manifold. I have replaced the diaphragm (0226) and Seal retaining brush (0216) in the DDM. Unfortunately, the leak is still there. Any...
Back
Top