  1. H

    Heatline Solaris question about increased DHW output

    Hi Mehran Thanks for your reply. Is that the current spec sheet or prior to the changes?
  2. H

    Heatline Solaris question about increased DHW output

    Guys When Heatline changed the Solaris DHW output about 18 months ago, they up rated the 24Kw to a 30Kw and 30Kw to 35Kw. I was given to understand Heatline changed the gas restrictor & plate heat exchanger only, is this correct? or did theyalso make changes to the Gianonni Heat ex, is it...
  3. H

    How to damproof a soil retaining wall

    Thanks for your replies.
  4. H

    How to damproof a soil retaining wall

    Hope someone can offer some advice (other than "don't do it, you mad"!) We are about to build a conservatory in to a sloping garden, rather than have a path with a retaining wall holding back the garden. I thought about having a dwarf wall to the conservatory, approx 600mm high, and would...
  5. H

    £orgi - lost bid to Capita for new gas safety scheme

    ££££orgi has lost the bid to run the new gas safety scheme from 2009, may bring a few smiles RGI's http://www.hse.gov.uk/gas/domestic/safetyreview.htm
  6. H

    Unsuccessful work done to cure cold rads

    ChrisR I'm interested in the tachometer you use to check pumps with as I have never seen one, where do you get these from? how do you use it? Thanks I would also add to the OP to turn off all the other rads and open each one that is not working one at a time to prove if its blocked or...
  7. H

    Ideal

    If a boiler or part is replaced under warranty, it will only benefit from the remainder of the warranty period and not start with a new warranty. That is standard procedure in our and many other industrys.
  8. H

    bleeding rads

    It may not be air you are bleeding but hydrogen produced by an electrolytic reaction between dissimilar metals. To test, hold a jar above the vent whilst releasing some gas, Light a splint then blow out, see if it re-lights when placed immediately into the jar. If this proves to be the...
  9. H

    Ideal Classic NF 80 Combination Boiler - noise

    Your problem is the wax thermostat.
  10. H

    Salus wireless stat

    Salus have been making OEM products for years for other major manufacturers before launching their own range. The RF stats are very good and simple to use.
  11. H

    Ideal Classic - do I keep it?

    The difference with your earlier PCB 25, it will have the wires coming off the board, rather than all molex connections as per the ebay board, but it will fit.
  12. H

    Ideal Classic - do I keep it?

    The tapping the boiler you mention can be either as mentioned above, the fan relay is sticking on the PCB or at the start of the ignition sequence the air pressure switch has to prove it self closed before bringing the fan on to open it. To prove, get someone competant to check - when the...
  13. H

    Ideal Classic - do I keep it?

    Classics are very good boilers. You say you think its the PCB faulty, what is the boiler doing? Are any of the LED's on the pcb on Does the fan run? Do you here sparking?