Search results

  1. M

    Baxi 105e no hot water to shower

    Done some searching for answers on this but nothing quite has the same problem im having. Basically the boiler is working fine for heating, cold water and hot water but not for the shower. When i switch on hot tap, the boiler fires up, lights come on and water gets hot. When i switch on...
  2. M

    Kitchen end panels

    I'm pretty much completed fitting my new kitchen and just have 3 end panels to go on. So far all end panels have been fitted to the ends (naturally!) and are screwed through from the inside with no problems. However, these last 3 are fitted to a being fitted where the kitchen has a 'return'...
  3. M

    baxi 105e - no heating and its getting cold !!

    have a baxi105e boiler and am having trouble with the heating. - boiler pressure is fine - all rads have been bled - plumber has been out twice and replaced the pressure gauge which was leaking and today checked and adjusted the pressure on gas valve and he was confident that would sort...
  4. M

    baxi 105e - radiators not heating

    starting to get a bit cold so decided to stick the heating on for the first time in ages, boiler fires up and goes through correct procedure and no fault lights and all seems fine. however none of the radiators actually seem to heat up. ive gone round and checked the 4 upstairs and one in the...
  5. M

    baxi 105e zero pressure

    had a baxi 105e for about 10 years and no major problems in that time and always had it regularly serviced. about 3-4 weeks ago it had an annual service and only problem was that the discharge pipe outside had a continual drip and the guy checked it and sorted it so no longer any drip...
  6. M

    bosch exxcel dishwasher went bang !!

    came home today and was expecting dishwasher to have finished running a cycle but instead all lights were off and it had stopped midway through. thought the fuse must have blown in the plug so i changed it and switched it back on and all was fine for about 30 seconds and then a loud bang and...
  7. M

    baxi 105e luke warm water when taps on full flow

    noticed my boiler only producing luke warm water when using the shpwer/bath or bathroom sink tap. after some trouble shooting ive found that if any tap or shower is on full blast i only get luke warm water around 50 degrees and it wont get any hotter, if i reduce flow rate to around half the...
  8. M

    luke warm water on a baxi combi 105e

    noticed that the hot water temp never seesm to go above 50 degrees recently, have checked the shower, bath and kitchen and bathroom sink tap and all are the same. even with the boilet water temp turned all the way up the temperature reaches around 50 and then stops heating any higher, its not...
  9. M

    radiator not heating up properly

    had a problem with one radiator in the house for a while now. when the heatings on all radiators heat up fine and work perfectly, the living room one never heats to the same temp as the others, even if thermostat is on full it will only be warm at best. thought i had found the problem when i...
  10. M

    Baxi 105e fault light flashing

    hi, hoping someone can help me with this, had a baxi 105e for about 8 years and in that time the PCB and diaphragm have both failed and been replaced. now its started with a new problem, when CH or DHW is on it will run for a short while and then the fault light for 'fault on central...