    y-plan not calling Broag system boiler

    Hi D_Hailsham Please look at page 38 of installation/ service book supplied with boiler
  2. W

    greenstar junior 24i problems

    Hi if you have a built in timeclock i have had this problem and found that the built in timeclock was faulty, if you just unplug it from the pcb if it's your problem the heating will work.
  3. W

    y-plan not calling Broag system boiler

    The Parameters are settings in software used for different situations The 24S is factory set for 2=CH on and DHW off all the Avanta range use the same pcb's so the parameters have to be set to suit ie Combi, System,Ngas,Propane etc.
  4. W

    y-plan not calling Broag system boiler

    Hi are you sure you have set Parameter 3 as already suggested by boilerman2? Do you know how to do this? using the +,- and enter buttons.
  5. W

    g/w betacom

    Heard they are rubbish, IMHO would look at Broag Remeha Advanta boiler range.
  6. W

    ariston 27mffi pain in the ass

    Usually the sensors/thermistors on these boilers, you will need to isolate on pipes below boiler and drain boiler to replace them.
  7. W

    ARISTON MICROCOMBI 23 MFFI

    Hi i'm talking about Micro Genus 23 MFFI which is the MK1 model, the on/off switch on these isn't a push switch are you talking about a different model?.
  8. W

    ARISTON MICROCOMBI 23 MFFI

    Hi the potentiameter for on off switch is in wrong position, you will need to turn it around to find correct position ie 180 degrees.
  9. W

    Help identifying part

    Hi it's a safety valve, designed to lift and relief pressure it's been leaking by the looks of it.
  10. W

    Will central heating help with condesation

    Hi condensation requires ventilation not heat, it forms on glass single glazing more because of the difference in inside/outside temperatures. Dehumidifiers work well along with ventilation in combating the problem,
  11. W

    No heating unless Hot Water is on

    Hi look for problem on m/valve, if You have a 3 port valve that could be your problem.
  12. W

    potterton flamingo 20 30 c/heating promblem

    Hi You need to look for external controls problem, as boiler is working, look for programmer calling for heat, roomstat calling for heat, m/valve etc.
  13. W

    wocester 350- confused!

    Red light means low water pressure, You need to refill system, look in faq's on how to do this.
  14. W

    Christmas Rope lights

    Hi Guys update I made a mistake they cost £1.97 a metre and they haven't gone o9ff they have sections between cutting points which don't light from the start, we are checking them now before they are strung, also they are connected to catenary wires. Thanks for your replies
  15. W

    Christmas Rope lights

    Thanks for your reply, these rope lights were bought from QVS and cost approx £1 per metre is that what you would class as cheap or not?
  16. W

    Christmas Rope lights

    Hi all we are fitting rope lights on an Estate, they vary in length and are being fed from one of the lights on each block, we have installed some which are approx 15metres in length they are 240volt rope lights they have been on for approx 18 hours and so far sections of them appear to have...
  17. W

    Netaheat 10/16E gas valve

    Hi if you have a Neta-Heat 10/16 electronic boiler the gas valve is now unavailable, but if you have a Mk2F boiler the valve is still available, this is the one with the Mercury switch, funny enough this is the oldest of the two.
  18. W

    U Values

    Hi if you do a search online there are lots of heat loss calculators which will tell you all the U values.
  19. W

    Ariston micro genus 27 MFFI

    Hi i have the Ariston Micro Genus mk1 on a PDF file, but i don't know how to send it.
  20. W

    Ideal Classic Gurgling Badly

    Probably needs system cleaning kettleing noise more apparent when on hot water only due to smaller circuit, try turning boiler stat down.