  1. J

    Installing Texecom Connect Smartcom

    Hi I installed the alarm panel Elite24 over 10 years ago , and have decided to add smartcom,Flashed the firmware from 2.01 to 5.02 and connected smartcom using a ethernet cable.Problem is I can not get it to work even though I followed the youtube tutorial,It says incorrect config call...
  2. J

    Dusk sensor

    Im after a dusk to dawn sensor which is able to switch LED's about 8 watts.I have Seen http://www.ebay.co.uk/itm/Weatherproof-IP44-Dusk-to-Dawn-Switch-Sunset-Sensor-Outside-Mains-Lighting-240v-/400337759677?pt=UK_BOI_Materials_Supplies_Electrical_ET&hash=item5d35fd6dbd but says not...
  3. J

    Intermediate Light Switch

    I know I can use one of these to replace a 1 way switch but will it work with 2 way switching as I have found the type I need at a good price on Ebay.thanks
  4. J

    UPVC window sash

    One of the sashes on my windows lets through some wind noise on the hinge side,after further investigation it looks like either the frame or sash has bowed a touch.Any tips how I could get this to reseal as the windows are in good condition and are about 15 years old
  5. J

    PIR for shed

    Is there specificate type of PIR that will be reliable for a smallish shed/workshop,I have contacts on the doors but wondered If I should have PIR as well in case the window is broken and gain access even though its quite small.I don't want false alarms due to heat ect.Are the microwave PIR's...
  6. J

    New combi flow and return

    I said I would ask here ,Is it good practice to tap in to the 15mm pipework feeding a radiator for the main heating flow and return on a combi boiler.This has been done by a heating firm installing a new combi.It seems to work OK
  7. J

    open door alert

    Can any one tell me how to program a chime when the entry exit door is opened when the alarm is not armed on a texecom 24 premier Thanks
  8. J

    Door contact for UPVC frame

    Im about to have a composite door fitted in a UPVC frame,has any alarm engineers fitted a recessed contact in to a upvc frame as the firm fitting say you can not drill the frame which I find strange as they drill fixings in it.Im not keen on the flush contacts or is there another way of doing...
  9. J

    Dimmer wiring

    Why is it that when my lounge dimmer on 2 way lighting is on and when I put a neon tester on the earth it lights up but does not give any shock.This includes the back box even with the earth disconnected from the switch.Is there a fault
  10. J

    Hob/Oven wiring

    I Am about to replace my single oven with a bosch which is rated at 16amp (3.5kw).At present the old oven and hob is on a 32 amp breaker connected via a 6mm cable with 2 separate connection units.Is it Ok to connect the oven 3.5KW and hob which has a total rating Of 6.5kw on the same 32amp...
  11. J

    Entry /Exit zone

    Have set up my texecom with 2 entry/exit zones. 1 is front door which I have 2 pirs set on guard access as they can just see you when arming/disarming which works ok.Problem I have is when I arm the system and then enter via back door (entry exit zone 2 ) the alarm goes off when the same 2...
  12. J

    Part Arming Texecom elite

    Hi is there a way to set a part arm to internal siren only at night only thanks
  13. J

    Zone Setup

    Have now got to the stage of programing my texecom Premier24 and after some tips as the best way to set it up with wintex.I want to be able to arm downstairs at night the complete house when out and also the workshop at night and when out.Is it best to set them all as 1 area ie A and into 3...
  14. J

    USB Coms lead

    Have finished the wiring of my texecom panel thanks to some help on here.Now just had a look at the programing whick looks very complicated using the keypad. Is http://www.ebay.co.uk/itm/Texecom-Premier-Elite-USB-Com-/281170153664?pt=UK_Burglar_Alarms&hash=item41770c10c0 lead correct as I may...
  15. J

    Door Contact Readings

    Hi Im in the process of installing a texecom system with no previous experience of them and trying to do some testing as I go .Installed all the pir's with EOL wiring which I think are OK. Now at the stage of doing the door contacts.What I have done is bridge the reed switch contacts with a...