Boiler size Help required

Joined
19 Sep 2011
Messages
74
Reaction score
14
Location
Glasgow
Country
United Kingdom
I'm replacing a back boiler with a combi boiler for a work project (i'm an apprentice) and I have calculated the radiator output from using their sizes and checking them against radiators from TDL - Trade Distribution Ltd, with all 6 adding up to 8.27kW. Its a bungalow house so i knew the figure would be a bit lower but i was just wondering if their was anything else i need to take into account like how systems req 3kW for hot water. I have just came into the combi boiler module so dont know all the logistics.
Thanks anyone who can help.[/b]
 
Sponsored Links
You don't need to add 3kw for a combi boiler, combi boilers are generally sized on hot water demand and the performance of the water main rather than the radiator heat output requirement
 
I have calculated the radiator output from using their sizes and checking them against radiators from TDL - Trade Distribution Ltd, with all 6 adding up to 8.27kW.
You are making the false assumption that the radiators are correctly sized.

Current practice recommends using a whole-house Boiler Size Calculator.

However, as you are installing a combi boiler, this has to be sized for the HW requirement. This means measuring the incoming cold water and pressure. A boiler needs to deliver 2.5kW for each litre/minute to raise the temperature by 35C. So a 40kW boiler will handle a flow rate of 16 litres/min.
 
Sponsored Links
Thanks for the help, its just a written project so i have to just assume the rads and pressures are all correct. Going to go with a 24kw for it going by whats been said
 