Hi,
To start with, I will be getting a qualified professional to install my EV charger. However, in preparation, there are some things that I would like to understand a bit about before engaging someone to do this work.
My home was fully rewired in 2019 and hasnt been touched since so is a clean installation.
The meter box is an external recessed white box at my front door with a 100A main "fuse". The 25mm (and 16 mm I assume for earth) tails then run from there to three henley type connectors in my cloakroom (which is in the middle of the house). And split into two consumer units.
I have an attached garage and ideally would like the EV charger to be located on the outside front wall of the garage beside the main roller door.
I do have two spare blanks on one of my consumer units. I am assuming that all wiring can be carried out from my cloakroom and that 10mm cable will be required for the EV.
Will I need a new CU to serve the new EV charger or can this be wired from one of the spare blanks in my existing CU?
If no new CU is needed, will there just be a 10mm T&E cable run from this existing CU to the EV charger.
If a new CU is required to serve the EV charger - would this most likely be located in my cloakroom and take an additional feed from the henley connectors (I assume using 25mm tails?); and then 10mm T&E from the new CU to the charger? Or will the new CU need to be located in the garage? If so, will the supply bacles ceom from the henley connectors? Can the new CU be in the garage, or must it be outside?
Can the wiring just use normal grey T&E or must it be the round black cable I see used in many videos (all wiring will be internal).
Sorry for all the questions and hopefully they are fairly clear.
Thank you to anyone trying to answer.
To start with, I will be getting a qualified professional to install my EV charger. However, in preparation, there are some things that I would like to understand a bit about before engaging someone to do this work.
My home was fully rewired in 2019 and hasnt been touched since so is a clean installation.
The meter box is an external recessed white box at my front door with a 100A main "fuse". The 25mm (and 16 mm I assume for earth) tails then run from there to three henley type connectors in my cloakroom (which is in the middle of the house). And split into two consumer units.
I have an attached garage and ideally would like the EV charger to be located on the outside front wall of the garage beside the main roller door.
I do have two spare blanks on one of my consumer units. I am assuming that all wiring can be carried out from my cloakroom and that 10mm cable will be required for the EV.
Will I need a new CU to serve the new EV charger or can this be wired from one of the spare blanks in my existing CU?
If no new CU is needed, will there just be a 10mm T&E cable run from this existing CU to the EV charger.
If a new CU is required to serve the EV charger - would this most likely be located in my cloakroom and take an additional feed from the henley connectors (I assume using 25mm tails?); and then 10mm T&E from the new CU to the charger? Or will the new CU need to be located in the garage? If so, will the supply bacles ceom from the henley connectors? Can the new CU be in the garage, or must it be outside?
Can the wiring just use normal grey T&E or must it be the round black cable I see used in many videos (all wiring will be internal).
Sorry for all the questions and hopefully they are fairly clear.
Thank you to anyone trying to answer.