Recent content by bcliff13

  1. B

    triton pc2100 shower

    I have a Triton pc2100 shower that when turned off still drips unless really forced shut. This is the second unit i have had that picks this problem up. I tried the service kit that Triton suggested and this was no good. Is there a repair or should i bin it and get a different system. I do like...
  2. B

    Icon 23 Hermann- Glowworm.. Diverter valve

    Many Thanks to all you Gas Guy's 4 your advice my Icon 23t is now running like a new boiler instant hot and very quiet running. Most important than all this i have a new boiler fitter mate who thinks this is just another simple boiler that he dont mind working on for a fair price. Brian..
  3. B

    Icon 23 Hermann- Glowworm.. Diverter valve

    New diverter v/v now in water still not to good. Nice guy from the board suggests new heat exchanger and a Magnaclean installed for £261. Is this the better option rather than Power flush. Or should i just cut my losses and buy new boiler. I have already laid out £210 the Gas guy said over a...
  4. B

    Icon 23 Hermann- Glowworm.. Diverter valve

    Thanks for that petit_pablo i know £60 is a little optimistic and £300 is a rip off. I think ill go with British gas 1 time fix fee for £210 including the parts and get my £75 back i paid for the diverter valve. Do you think this is the way to go...
  5. B

    Icon 23 Hermann- Glowworm.. Diverter valve

    The diverter valve on our 9 year old boiler has failed. I purchaced a genuine replacement and arranged for the guy who services the boiler to come round . he started stripping down then decided he couldn't do it for less than £300 quid. I said 5 years ago a gas fitter charged me £60 quid which...
  6. B

    is it legal

    Can a gas safe (corgi)fitter still fit a non- condensing boiler if it is new and in the box.
  7. B

    (glowworm) icon 23t prv lift

    thanks for the reply. The pressure slowly increases. to about 3 bar
  8. B

    (glowworm) icon 23t prv lift

    I have a 8 year old icon23t combi boiler which has always been serviced and basically well maintained, i like many other people have just started using the c/heating and find when it's turned off that over a few hours the pressure drops. During the summer when running water only no issues...
  9. B

    icon23t v/v replacement pressure v/v passing (help)

    Thanks for the advice superdupergasman i think you may be on the right track .The problem i now have is locating the fault.I know where the prv is and it lifts if i turn the top anti clockwise do i need to get a corgi guy in as this is water side and not gas side any help most gratefull, also...
  10. B

    icon23t v/v replacement pressure v/v passing (help)

    After changing a leaking heating return v/v on my combi icon23t boiler and refilling system have now found pressure relief v/v passing even though system at no time has been put above 2.5 bar pressure, it continues to pass untill system shuts down. any advise would be most welcome.
  11. B

    Icon 23t heating flow v/vreplacement

    Cheers Agile I have tried this and it did reduce the drip and actually stopped it when the system runs hot . The lady of the house cant live with the thought that it may return and i cant live with her nagging. I think the v/v change is going to happen if i freeze the infeed pipe will much...
  12. B

    Icon 23t heating flow v/vreplacement

    Thanks James The boiler is downstairs but the freeze option is something i overlooked this is probably the way for me to g
  13. B

    Icon 23t heating flow v/vreplacement

    The heating flow valve on my boiler has developed a drip i have brought a new v/v to fit but would like to know if its possible to do the job without draining the whole system down. the system is working fine apart from this small drip which eventually causes pressure in the loop to drop and...