    Anyone seen this sarking board before?

    Hi guys. I'm looking to convert my loft space and have noticed a few of the sarking boards are sagging in places. The boards look like compressible fibre filler boards. Certainly not standard softwood sarking used in Scotland. Anyone seen this used before for this purpose? I'd rather proper...
  2. D

    15mm TRV on 8mm Microbore

    Ah I like the look of those reducers, will defintily go with them - Unless anyone has any other suggestions?
  3. D

    15mm TRV on 8mm Microbore

    Richard I don't have the maxi-twin type valves, just standard manual valves and lockshields. The units dont seem to be branded but they have half decent reviews (screwfix)
  4. D

    15mm TRV on 8mm Microbore

    The raditaor I am after come with valves but they are 15mm. I can always order 8mm ones but will save a fair amount given I have 8 radiators to replace
  5. D

    15mm TRV on 8mm Microbore

    I am looking to fit new radiators throughout the house which currently has 8mm microbore to the radiator valves. Currently has really old rusty radiators with manual valves etc. I've decided 15mm TRVs will be best to allow future changing of pipework when a new boiler is installed (hopefully...
  6. D

    extending Loft hatch project - need help asap

    Since you are cutting a ceiling joist it is always wise to double up the joists to each side of the cut section (you are removing "b" so add extra timbers to "a" and "c"). This compensates for the removed strength. Common practice for this type of thing and velux roof lights etc.
  7. D

    Another stud wall removal to make kitchen-diner

    If it is spanning parallel to joists and is not directly below the higher level stud wall it is unlikely to be load-bearing and can probably be removed. What is the full span of the trusses? Before you remove it though make sure the upper level stud wall is properly supported off...
  8. D

    Vectra 1.8 petrol 2004 EML light

    Does it effect the driving of the car? If not, don't worry about it. I had 2000 vectra with EML on for a full year and it was fine.
  9. D

    Ferroli Optima 701 DHW issue, Fault Finding shown

    Ah wait, do you mean doing a quick bypass to see if the switch is faulty?
  10. D

    Ferroli Optima 701 DHW issue, Fault Finding shown

    You mean to test if it's a wiring issue instead of a faulty flow switch? Hadn't actually thought about that, but definitely worth a shot, thanks!
  11. D

    Ferroli Optima 701 DHW issue, Fault Finding shown

    I have a Ferroli Optima 701 boiler which is not producing hot water. CH works fine. http://i10.photobucket.com/albums/a123/davekgti/IMAG0325.jpg When I have the hot tap running I have LED's 1 and 4 ON which is OK However, LED's 2 and 6 are OFF. This leads me to believe that the DHW...
  12. D

    Wiring in froststat

    problem sorted cheers chaps
  13. D

    Wiring in froststat

    Im replacing the controller and sorting out the very very messy wiring linking the system together but im unsure where the froststat should go I have the S plan system and all electronic parts are Honeywell, valves, controller and both cylinder stat and frost stat Am i right in saying that...
  14. D

    Re-plumbing System

    ok thanks ill try a poweflush first then, ive got the worst of the crap out now so that should fix it cheers for the help guys!