Recent content by diybristol

  1. D

    Stop valves on New Toilet/Sink - Water Standards

    Hi I am fitting new sink and new toilet in en-suite in an extension, the question is I think I need a stop water fitting on the toilet for waterstandards, can this be fitted anywhere along the pipe or does it have to be within a certain distance of the toilet? Then with the sink, do you...
  2. D

    Ideal Standard Dual Flush - New Fit and Leak on Old!

    Hi , I have a Ideal Standard Cistern with a Push Button Dual Flush Valve in it, and have a new one to fit in an en-suite... now I have two problems... The first problem is nowhere in the instructions does it say how to fit the pipe to the inlet so you can fill the cistern... as it stands...
  3. D

    Soil Pipe Branch issue - Ensuite, to Saniflo or Branch off?

    thanks, but can't take up floorboards as under bath in new bathroom which I just don't want to take apart for this. the trouble is you got a bath going in lower and a sink higher up the pipe and obviously the original toilet too, the whole thing is a nightmare... Is there a specialist sort...
  4. D

    Soil Pipe Branch issue - Ensuite, to Saniflo or Branch off?

    thanks for warning, but surely this is the easier way rather than what I have to do otherwise, besides if mainly used for number 1's then can't go that wrong surely.
  5. D

    Soil Pipe Branch issue - Ensuite, to Saniflo or Branch off?

    I enclose a photo of our current waste system which has 110mm Grey Marley Soil Waste and simply runs one toilet into it, as we now have an extension and on the other side of the soil pipe we wish to add a toilet and sink. what I intended to do is to get this out and put a T-branch...
  6. D

    TRV Faulty? HelP!

    thanks, bought a new one, still didn't work was a massive airlock in system! took all afternoon to sort out. Thanks for help!
  7. D

    Leaking Radiator at Thermo Joint

    Thanks Doitall! I took em all off replaced, with plenty of PTFE, looks like mate who did it put 2 wraps of ptfe! Just bit of problem with downstairs rad not heating, but will write back if still issue later, trying a few things now.
  8. D

    TRV Faulty? HelP!

    nah it was done seperately, the thing is the flow was hot when I first put on heating, so it was getting there, but nothing going thru
  9. D

    TRV Faulty? HelP!

    yeah brand new on all rad's its a Drayton RT212 , others work fine. what do you reckon?
  10. D

    TRV Faulty? HelP!

    Are TRV's meant to be fitted on the Flow or Return, I am guessing that the flow is the hot pipe when the TRV doesn't let any water through? If I have fitted round wrong way will rads still work>?? cos can't get no water through either! I don't think it matters, but the other two rads are...
  11. D

    Leaking Radiator at Thermo Joint

    Thanks for coming back, I just turned em back on and they seem ok, but worried once boards down, why would the screw raise? pressure? Also on the other radiator I got such a minute drop of water, I am thinking is it worth doing, we are talking in an hour or so not even a drip, its only if you...
  12. D

    Leaking Radiator at Thermo Joint

    http://www.screwfix.com/app/sfd/cat/pro.jsp?cId=A236929&ts=93894&id=67670 its one of these valves, I just checked the other and that seems the same, I turned it so the line is vertical with valve which is off, the screw seems to rise and slight water seeps out, is this pressure? Do I really...
  13. D

    Leaking Radiator at Thermo Joint

    thanks for your reply breezer, yeah I did put two cut off on, the screw type, but when I just turned them off the screw kinda pops out a bit and is dripping water too, I managed to wind it back round but seems to be duff? does this happen often?
  14. D

    Leaking Radiator at Thermo Joint

    I just fitted 3 radiators on a extension linked into normal boiler system. One of the radiators is dripping very slightly from the thermo valve where it actually goes into the radiator thread, I have tightened it as much as I can and it still leaks :cry: Even though it would take a year...
  15. D

    Sticking Skirting to Wall - Gripfil Alternative?

    ok looks like Gripfil Max then
Back