Recent content by nozspark

  1. N

    Looking to purchase a Soldering Station

    Where I used to work we used the Pace MBTs,,, really good piece of kit for proffessional use; they are expensive, but IMHO you do get what you pay for and the parts will be available forever. It's no good buying something thats cheap with restricted or non existant availability of parts
  2. N

    Dishwasher fault

    I've had this happen twice on me a few years ago,, different dishwashers BTW Cables at the bottom of the door were either fractured due to their constant bending (opening & closing door) or were rubbing on the framework!!
  3. N

    Blagdon Powersafe Outdoor Wall Socket Kit

    This is a quote from the approved document P 2006 edition which I think could be helpful Page 9 k. The installation of prefabricated, “modular” systems (for example kitchen lighting systems and armoured garden cabling) linked by plug and socket connectors is not notifiable, provided that...
  4. N

    NICEIC electrician produces certificate years after job

    IMHO I don't think you'll get anywhere with this the work was carried out 4-5 years ago, in that time anyone could have tampered with it (that'll be his defence) and whilst he has issued a certificate for his work only a few weeks ago, it could be a copy of the original (which the previous...
  5. N

    Wiring in a wireless thermostat, help would be great

    Permanent Live & Neutral to L & N then remove link in boiler and connect terminals to COM & NO
  6. N

    2 way bedroom pullswitches ??

    What I tend to do is offer the client options and then do what they are paying me to do. I never blindly rewire a property like for like, more often than not they want extra sockets or want light switches moved or extra lights etc..
  7. N

    wiring a replacement 2 gang 1 way light switch

    I doubt it... have you disconnected the wires from the old switch yet? I hope not. You need to mark each wire and note which terminal its connected to before you disconnect them, then move the wiring across to the corresponding terminals on the new switch. Don't forget, if your new...
  8. N

    Discrete 240v mains socket

    I'd have to say yes as that's what the website says
  9. N

    Discrete 240v mains socket

    How about one of these? They also do hidden switches :wink: probably a :shock: price though.
  10. N

    wiring for lights connected to timer and photocell

    IIRC i think you can get both dusk/dawn and dusk + x Hrs photocells... however if you want the light to come on at dusk and off at say midnight then connect the photocell supply and timeclock supply terminals to permanent live & neutral then the output through the timeclock terminals... set...
  11. N

    Complete Kitchen Refit

    If you're doing lighting via plug/socket on a lighting circuit then I'd have thought that best practice would dictate round pin plugs & sockets?
  12. N

    resolved: MCB on but no power

    You should really replace the busbar as it's more than likely over heated
  13. N

    periodic codes

    Mine in bold Have a look at the ESC guidance, loads of good info in it!
  14. N

    Concerns on pre-insulated crimp terminals on solid conductor

    I had some crimps that felt loose a year or so ago.. I found that it was the crimps (Pik a pak - or something like that) SWA crimps seem to hold solidly. I have a SWA crimper BTW
  15. N

    2391 Practical Exam!

    I did the 2391 in 4 1/2 days. Written exam on afternoon of 4th day and practical on following morning.. then 3 months wait for the results/certificate