    Vokera Compact 29 Yellow light

    Meant to post an update to this ages ago and forgot ! Called vokera the following day who advised that a solid amber light with no operational faults was Hot Water Preheat activated. Can be turned off if reqd.
  2. T

    Vokera Compact 29 Yellow light

    Hi all. Replaced a HW thermistor on a Vokera Compact 29 today due to failure. Problem solved there. Noticed when I was finished that the Amber light is lit continuously (solid amber, not blinking). This is irrespective of wether the boiler is currently in use (demand) or standby (no...
  3. T

    Worcester 350 relay RL 1 buzzing loudly

    Hi all long time no speak :D Worcester 350 Combi with "built in" digital timeclock. Extremely loud buzzing/vibrating from Relay RL1 on right hand side pcb (the one with two boards linked with ribbon connector). Overheat Stat has continuity. Low Water Switch = Live on white, Live on...
  4. T

    Chaffoteaux et Maury CORVEC 45 open flue

    Could be primatic, Glasgow's full of the things. That aside, i still have no idea what the op is on about lol !
  5. T

    Vokera 80E "Divertor" prob.

    Hi guys n girls. Vokera Excell 80E. Rads heat up when hot water in use. Divertor kit fitted last week by a colleague of mine. I turned up today, tenant reported same fault as previously (rads heating up when hot water in use) so removed divertor kit to check if buckled/faulty/etc (it...
  6. T

    Vokera Excell 80SP slow-running fan

    Im almost positive that there is a switch activated by a diaphragm & pin arrangement that keeps the fan running without a demand for heat or water. Its been a while since ive seen an Excel right enuff but from memory its located below the hw assembly. I cant remember if the pin should be in or...
  7. T

    Myson Midas SFI Assistance req'd

    Thanks for the led explanation which i have printed off for future refernece and to the "senior technician" at Potterton for his assistance on the phone. Problem was cured today with a new airflow sensor, yes i was right the first time by replacing it on my initial visit to the property on...
  8. T

    Myson Midas SFI Assistance req'd

    Afternoon all. Boiler is : Myson Midas SFI GC no. 47-494-04 Intermittent fault on HW, CH appears to work as per normal. Fault occurs approx 1 in 3 times. Here is my description of what i noted when the fault occured and some previous work done on the appliance. The initial fault was crappy...
  9. T

    I really dont think this is quite what I expected....

    I love the way u started with "Remember me" lmao Anyhooooo, glad it all worked out in the end.
  10. T

    Baxi Combi 133HE Plus - PCB failure

    :lol: should've seen that coming ! TAXI !!!!
  11. T

    Worcester Greenstar 35 CDi

    Im assuming u mustve had hot water over the weekend so it could be a gas pressure problem. I dont think it's fair to say anything wrong about the guy working over the weekend, maybe he wanted sum "overtime". In any case, why not just phone back the installer ?
  12. T

    Baxi Combi 133HE Plus - PCB failure

    I think there has been changes to this PCB now, though i have not had that confirmed as yet. Anyone ? I seen one that actually started smoking as i worked on the boiler which was a bit frightening lol !
  13. T

    Problems with Vaillant boiler flames

    Apart from sooted heat ex, if thats clear and flue is clear there may be a fault with the burner. I once saw one that had split at the side of 2 burner bars and was burning between the 2. Probs just needs a good service though !
  14. T

    Ideal Isar PCB's

    Fantastic, i look forward to replacing more then ! My gaffer is trying to save dough by passing some back to Ideal which are just out the guarantee period. Aparantly they give a 2yr warranty when fitted in a new build property which is handy to know. Have seen the famous water leak a couple...