Recent content by Weedrip

  1. W

    Gas installer not gas safe

    Sadly I am not aware of any laws that make dubious morals an offence. the persons committing the offence are the contractor and the person undertaking the work in an unregistered capacity, as they would in such an example at the very least commit an offence under the gas installation and use...
  2. W

    Gas installer not gas safe

    Lol..... I have indeed been given conflicting advice, I have also been given incorrect advice and when challenged they have had to back track but that's another story. Lets put our brains in gear here for a moment. what other avenues do you know of for an unregistered installation to get...
  3. W

    Gas installer not gas safe

    Then Tony you need to talk to Gas Safe. A recent example 8 weeks ago [ish] I was asked to certify a boiler by a domestic customer so that they could get BG to register an install that was about a year old. For the record I neither know or care why the BG would do such a thing but the customer...
  4. W

    Gas installer not gas safe

    I think some of you need to talk to gas safe regarding post commissioning a boiler install. The only persons who have committed an offence under the installation and use regulations are the building company who have knowingly engaged an unregistered person [allegedly] to preform work as defined...
  5. W

    Do Grundfus Pumps lose efficiency?

    Pump impellor can become blocked over time the veins are quite narrow and they trap small particles and then collect more. isolate pump valves undo the 4 allen bolts and gentle release the head from the body. do be sure the pump valves are isolating properly first tho. a paper clip can...
  6. W

    Installing a NEST to a Vaillant Turbomax

    The lack of any measurable voltage at the original stat is probably because there is no Neutral on 2 to measure the voltage via lives on the red and black. which also probably is why your original stat was not working as expected.... perhaps! if you are unsure of the connections probably...
  7. W

    Will this gas valve work with my boiler?

    You are concerned for your safety but are willing to perform work on a gas appliance? I think perhaps you have a screwed perspective.. funny old world....
  8. W

    Cast iron radiator bushes

    A decent blow torch and 24" stillsons at least. Get it hot, it will shift.
  9. W

    Radiator bleed valve sheared off

    Try Myson? "Can I drill out & re-tap bleed valves on old radiators? If your radiator is a Myson Premier two tapping radiator, manufactured before June 2003, the air vent is in line with the rounded top of the radiator. This vent may be re-tapped with a No.10 32UNF tap (4.1mm drill size)...
  10. W

    Electrical test procedure on gas boiler advice

    Your probably right about asking a sparky londonboy. How does that work with double pole isolation on a fused spur?
  11. W

    Is my tank big enough to get a bath full of water out of?

    Only picture by the OP I see is the one of a cylinder pretending to hide. never had a problem with getting a 36" of the shelf of my merchants! you also forgot 'humourless prat' but oh well..... :roll: I best leave it to you experts......
  12. W

    Is my tank big enough to get a bath full of water out of?

    Bit harsh I feel, being a short fat bloke who happens to be a plumber. who fits one of your stereo-typical types :cry: Perhaps we could blame the manufacturers for only providing a top entry immersion port std fare in most merchants would be 11 - 27 - 36 heaters. check the length of the...
  13. W

    Expensive upgrade of incoming mains-worth it?

    Hi here is a link to your valve type. its not 22mm connections but 3/4" unions, however the internals are probably not dissimilar judging from your pic. http://www.caleffi.com/en_IT/Technical_brochures/01085/01085.pdf do you know or can you judge the distance from the main boundary...
  14. W

    Expensive upgrade of incoming mains-worth it?

    First off I don't really understand what Agile is on... Put simply flow through a pipe is based on velocity x bore, [for the pedants yes I know there's more to it but lets accept the premise for the sake of simple explanation.] The deciding factor in your case is the bore of the PRV, its...
  15. W

    Connecting small fuel tank for oil heating.

    drill hole to suit a [Conex 15mm Tank Connector 321] pass a piece of string with a nut tied on the end through side hole and feed out through the screw cap at top. pull long length of string and feed through the tank connector tie a washer behind the tank connector and draw the connector...