Britony combi SE: where's the flow switch hiding?

Joined
29 Mar 2005
Messages
13
Reaction score
0
Location
Manchester
Country
United Kingdom
Morning.

Quick explanation of why I'm looking for this elusive little gadget:

DHW only fires when the hot water tap is turned to delivery quickly, but under those conditions the water passes too quickly through the exchanger to get much heat in it. Any slower and the boiler shuts off the DHW.

So, after much reading, I'm looking at the flow switch.

Thing is, where is it? The documents I got with the combi (in 2001) only show the device in a schematic diagram - it shows no pictures. A quick google (and eBay) shows a neat looking gadget which looks simple enough to find, you would think.

Interestingly, my doco says the following about replacing the flow switch:

14. DHW Flow Switch
Disconnect the electrical connections undo the securing clip and remove the microswitch; reassemble in reverse order.

The pics I found around the globe suggest that there's more to a flow switch than just the microswitch - possibly involving a piston?

Here are the pics I just took of the combi.

Where's the removable flow switch?










This is what I found on eBay, part number (600)81471




Can anybody help me find my flow switch?

Thanks.


21/12/2011: edited title to replace "80" with "SE"
 
Sponsored Links
follow the cold inlet pipe into the boiler(make sure electric and water are isolated--!!!) that will lead you to flow switch. these types of switches normally only require to be cleaned out as the magnet inside gets built up with deposits but either way cheap part, easy job
 
... these types of switches normally only require to be cleaned out ...
Thanks for the quick reply, but my question remains... where is this switch? I cannot locate it.

As for cleaning it out (if I find it) if the eBay part I pictured is anything to go by, it doesn't look like it comes apart.
 
Diaphragm probably needs replacing...middle of the second picture down. Your ebay part is for a completely different boiler.
 
Sponsored Links
Thanks for all the replies. Looks like I got a few things to look at, starting with the clipped-in thing with a fallen-apart diaphragm :(



by the looks of it the part ya got is for britony 80, the boiler ya got is a se
I didn't order that part but very nearly did; this forum just saved me £21! My doco says I have an "80" but as you say, the internals say its an "SE". Brilliant.
 
flow regulator will be the problem ,knurled plactic black piece hed in with a clip on the front follow the water inlet up ,turn cold off open tap and remove it will have fallen apart
Bob on.

Removing and dismantling this




Showed me the white spring retaining piece had sheared :(




Tried eBay and a few other online stores, cannot find a single source :(
 
You will probably be forced to get it from Parts Center where they are both expensive and in most branches not very helpful.

Tony
 
You will probably be forced to get it from Parts Center where they are both expensive and in most branches not very helpful.

Tony

I'll check them out if they're online. Thanks for the pointer (and the warning)
 
Got good results using the actual part number 1301952. Around £15 delivered. Result.
 
I know this thread is old now, but to add my experience....

I had the same symptoms, couldn't get DHW without high flow rate, but I could turn it down afterwards to get the temperature up. And then on Sunday it must have 'gone' completely as nothing could persuade the old bastard Britony SE 100 to fire up DHW. I could see the hydraulic actuator was not moving down to call for DHW, so might have been the diaphragm or....ah this flow switch is in the path....bit of searching done...

Drained down DHW. Took the flow regulator out, completely knackered. Found most of the plunger and the spring, but the end-piece (X shaped piece of plastic on the opposite end to the knurled end) was completely gone ! I wonder where...come away in bits and out through a tap perhaps.

Any how, got a new one of those....from PartsCentre now costing 21quid plus VAT for the SE100 version. Very easy to replace. Remove old one, clear-out a bit of perished o-ring, and used silicone grease on the o-rings of the new one. I notice the X end piece seems to be of a different type of plastic to the rest of it, might explain why that disintegrated as opposed to the main body. Not an item in stock, had to wait overnight and pick up in store today.

Also renewed the diaphragm because that was looking worn, although still in one piece. Replaced and greased the actuator which pokes out of the bottom of the diaphragm assembly and moves the 3 port valve including pressing on the 'DHW demand' microswitch. Careful reassembly of the diaphragm and renewal of the o-rings...no leaks. Perhaps I could have got away with not replacing the diaphragm but the actuator was quite stiff and probably needed cleaning up and greasing.

Cheers to gordongas and people in other threads who documented this one.

Whenever I get a fault with this joyous heap it spurs me to think about getting a new one, but then I fix it and feel a bit more attached to it. If the gas side starts playing up it will be out !
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Sponsored Links
Back
Top