  1. D

    Should I repair or replace my slate roof

    Well I have never done a slate roof where the slates are not on the batten, I don't know the consequences. Should have used slate and a half on the verge. Has he installed soakers on the abutment side, normally ally or code 3 lead.did he mentioned ventilation at eaves or high level or insulation...
  2. D

    Should I repair or replace my slate roof

    Is there a reason why the top of the slates are not on the bottom of the battens?
  3. D

    Boiler wiring /spur

    Will look it up. The reason for it is for safe isolation
  4. D

    Boiler wiring /spur

  5. D

    Boiler wiring /spur

    Or even unswitched
  6. D

    Boiler wiring /spur

    Think the regs are unstitched socket
  7. D

    Leaking stopcock with lead pipe

    Try to cut the lead pipe square, clean the outside of the pipe, you may have to file the pipe down a bit to get lead loc on. Normally 7 or 9lb Probably 7lb
  8. D

    What have you been doing today?

    Wishing you all the best Conny
  9. D

    CH pipework query

    Air seperator
  10. D

    Boiler Not Heating the Hot Water Properly

    It could be air lock around the cylinder. Post photos of cylinder and pipe work
  11. D

    Gas hob cabinet distance confusion.

    Manufacturer instructions overide British standard
  12. D

    Clark drain cover stuck

    Undo the screw's
  13. D

    Boiler flue within new extension

    No, do not use the boiler.
  14. D

    One in 10 biggest English councils risk bankruptcy over child protection bill

    Business rate, takes into account the cost of running a business and all associated costs. It's not all profits or wages
  15. D

    Unvented central heating losing pressure only in winter

    Looks like the cylinder temperature and pressure relief valve is connected to the heating system
  16. D

    Shower unit cubicle

    Room sealed boilers draw air from outside, open flue draw air from inside. Normally any open flued appliance above 7kw will require ventilation from outside
  17. D

    Shower unit cubicle

    Open flue boiler's are not allowed in bathroom's
  18. D

    Bathroom downlight - with changeable bulbs

    Ovia inceptor, Tri colour, ip65 You can adjust to change colour
  19. D

    Do i need to protect gas pipe?

    Yes
  20. D

    Do i need to protect gas pipe?

    A gas pipe behind the plasterboard should also be fully encased in dot and dab. Electric cable should have a minimum of 25mm separation. Check the regulations